The quality of reporting of diagnostic accuracy studies in glaucoma using scanning laser polarimetry.

机译:使用扫描激光偏振仪对青光眼的诊断准确性研究进行报告的质量。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: Scanning laser polarimetry (SLP) has been proposed as a useful diagnostic test for glaucoma. This study was conducted to evaluate the quality of reporting of published studies using the SLP for diagnosing glaucoma. METHODS: A validated Medline and hand search of English-language articles reporting on measures of diagnostic accuracy of the SLP for glaucoma was performed. Two reviewers independently selected and appraised the manuscripts. The Standards for Reporting of Diagnostic Accuracy (STARD) checklist was used to evaluate the quality of each publication. RESULTS: A total of 47 papers were identified of which the first 10 (from 1997 to 2000) and the last 10 articles (from 2004 to 2005) were appraised. Interobserver rating agreement of STARD items was high (85.5% agreement, kappa=0.796). The number of STARD items properly reported ranged from 3/25 to 19/25. Only a quarter of studies (5/20) explicitly reported more than half of the STARD items. Important aspects of the methodology were often missing such as participant sampling (reported in 40% of manuscripts), masking of the readers of the index test and reference standard (reported in 20% of manuscripts), and estimation of uncertainty (eg, 95% confidence intervals, reported in 25% of manuscripts). There was a slight increase in the number of STARD items reported with time. CONCLUSIONS: The quality of reporting of diagnostic accuracy tests for glaucoma with SLP is suboptimal. The STARD initiative may be a useful tool for appraising the strengths and weaknesses of diagnostic accuracy studies.
机译:用途:扫描激光极化仪(SLP)已被建议作为青光眼的有用诊断测试。这项研究旨在评估使用SLP诊断青光眼的已发表研究的报告质量。方法:进行了验证的Medline和手工检索英文文章,报告了SLP对青光眼的诊断准确性。两名审稿人独立选择并评估了手稿。诊断准确性报告标准(STARD)清单用于评估每个出版物的质量。结果:共鉴定出47篇论文,其中前10篇(从1997年至2000年)和后10篇(从2004年至2005年)被评估。 STARD项目的观察员之间的评分一致性很高(一致性为85.5%,kappa = 0.796)。正确报告的STARD项目数量在3/25到19/25之间。只有四分之一的研究(5/20)明确报告了STARD项目的一半以上。该方法学的重要方面经常缺失,例如参与者抽样(报告占40%的稿件),掩盖索引测试和参考标准的读者(报告占20%的稿件)以及不确定性估计(例如95%)置信区间,以手稿的25%报告)。随着时间的推移,报告的STARD项目数量略有增加。结论:SLP的青光眼诊断准确性测试报告质量欠佳。 STARD计划可能是评估诊断准确性研究的优缺点的有用工具。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号