摘要

High-level radioactive wastes generated during the processing of nuclear materials are stored in large underground storage tanks made of low-carbon steel. The wastes consist primarily of concentrated solutions of sodium nitrate (NaNO{sub}3) and sodium hydroxide (NaOH). Each of the tanks is equipped with a purge ventilation system designed to continuously remove hydrogen gas and vapors from the waste tanks while preventing the release of radionuclides to the atmosphere. Several intergranular cracks were discovered in the vent pipe of the purge ventilation system of a particular high-level waste tank. The vent pipe, fabricated from galvanized steel sheet, was connected to the final exhaust fan downstream of high-efficiency particulate air (HEPA) filters. The failure analysis investigation concluded that nitrate-induced stress-corrosion cracking (SCC) was the cause of the failure.
机译:核材料加工过程中产生的高放射性废物被存储在由低碳钢制成的大型地下储罐中。废物主要由硝酸钠(NaNO {sub} 3)和氢氧化钠(NaOH)的浓溶液组成。每个储罐均配备有吹扫通风系统,该系统设计为可连续除去废物罐中的氢气和蒸气,同时防止放射性核素释放到大气中。在一个特定的高位废水箱的吹扫通风系统的通风管中发现了几个晶间裂纹。由镀锌钢板制成的通风管连接到高效微粒空气(HEPA)过滤器下游的最终排气扇。失效分析调查得出结论,硝酸盐诱导的应力腐蚀开裂(SCC)是导致失效的原因。