首页> 外文期刊>Journal of Failure Analysis and Prevention >Failure Analysis of a Corroded Threaded Fitting in an Ammonia Refrigeration System
【24h】

Failure Analysis of a Corroded Threaded Fitting in an Ammonia Refrigeration System

机译:氨制冷系统中腐蚀的螺纹接头的失效分析

获取原文
获取原文并翻译 | 示例
           

摘要

A corroded threaded fitting on a direct-expansion ammonia fan-coil unit was found to be leaking in a refrigerated food-handling warehouse. Efforts to stop the leak by tightening the threaded connection resulted in the failure of the male fitting, causing a catastrophic release of ammonia refrigerant. Subsequent analysis of the subject threaded connection found that the threads of the male carbon steel fitting were severely deteriorated by atmospheric corrosion. The installation location of the subject fan-coil unit was such that it repeatedly experienced significant condensation and frost accumulation and, therefore, needed to be regularly defrosted. It was this combination of repeated condensation/frost accumulation and a cyclic freeze/thaw process which resulted in the accelerated atmospheric corrosion of the subject threaded connection.
机译:发现直接膨胀的氨气风机盘管装置上的腐蚀螺纹配件在冷藏食品处理仓库中泄漏。通过拧紧螺纹连接来阻止泄漏的努力导致阳接头失效,从而导致氨制冷剂的灾难性释放。随后对该主题的螺纹连接进行分析,发现外露碳钢接头的螺纹由于大气腐蚀而严重劣化。风扇盘管装置的安装位置应使其反复出现明显的凝结和结霜,因此需要定期除霜。正是这种反复凝结/霜冻积累和循环冻结/融化过程的结合,导致对象螺纹连接处的大气腐蚀加速。