A metallurgical failure analysis was conducted to determine the cause of cracking in several sections of copper refrigeration tubing. The tubing in question was part of a new mechanical design, implemented to mitigate fatigue failures of solder joints that had occurred in tubing systems fabricated under the previous design. A comprehensive metallurgical evaluation revealed intergranular fracture of the copper in a region of the tubing that had been significantly cold worked during manufacture. On discovery of a source of moist ammonia in the system, associated with the location of failure, inter-granular stress-corrosion cracking (SCC) was identified as the failure mechanism. A modified design, incorporating annealing of the formed copper tube section, was recommended to avoid future failures.
机译:进行了冶金学故障分析,以确定在铜制制冷管的多个部分中开裂的原因。有问题的管道是新机械设计的一部分,旨在减轻以前设计制造的管道系统中发生的焊点疲劳失效。全面的冶金评估表明,在制造过程中经过显着冷加工的管材区域中,铜的晶间断裂。在发现系统中的湿氨源与故障的位置相关时,将晶间应力腐蚀开裂(SCC)识别为故障机理。为了避免将来发生故障,建议进行修改后的设计,其中包括对形成的铜管部分进行退火。