首页> 外文期刊>Dementia and geriatric cognitive disorders >Comparison of the usefulness of brain perfusion SPECT and MIBG myocardial scintigraphy for the diagnosis of dementia with Lewy bodies.
【24h】

Comparison of the usefulness of brain perfusion SPECT and MIBG myocardial scintigraphy for the diagnosis of dementia with Lewy bodies.

机译:比较脑灌注SPECT和MIBG心肌闪烁显像在路易体痴呆诊断中的作用。

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND: Supportive features in the diagnostic criteria for dementia with Lewy bodies (DLB) include occipital hypoperfusion and decreased cardiac uptake of (123)I-metaiodobenzylguanidine (MIBG). In this study, we performed both brain perfusion single photon emission computed tomography (SPECT) and MIBG myocardial scintigraphy in the same subjects and evaluated their sensitivity to detect the characteristic features of DLB. METHODS: Twenty-five patients with probable DLB (76.8 +/- 5.1 years old, 10 male) underwent (99m)Tc-ethylcysteinate dimer brain perfusion SPECT and (123)I-MIBG myocardial scintigraphy. The results of SPECT were analyzed using a qualitative analysis program, easy Z score imaging system (eZIS), and an automated quantitative analysis program, 3DSRT. RESULTS: Qualitative analysis using eZIS demonstrated occipital hypoperfusion in 17 subjects (68%). The quantified mean blood perfusion in the occipital segment on the 3DSRT template was 40.7 +/- 5.03 ml/100 g/min (right) and 40.5 +/- 5.38 ml/100 g/min (left), and in 19 DLB patients these values were below the normal limit. Twenty-four of 25 subjects (96%) had decreased cardiac MIBG uptake in the delayed image. CONCLUSION: MIBG myocardial scintigraphy was superior to brain perfusion SPECT in detecting a characteristic feature of DLB. Our results suggest that combining SPECT and MIBG scintigraphy could increase the accuracy of clinical diagnosis of DLB.
机译:背景:路易体痴呆(DLB)诊断标准中的支持特征包括枕叶灌注不足和(123)I-甲氧苄基胍(MIBG)的心脏摄取减少。在这项研究中,我们在同一受试者中进行了脑灌注单光子发射计算机断层扫描(SPECT)和MIBG心肌闪烁显像,并评估了它们检测DLB特征的敏感性。方法:25例可能的DLB患者(76.8 +/- 5.1岁,男10例)接受(99m)Tc-半胱氨酸二聚体脑灌注SPECT和(123)I-MIBG心肌显像。使用定性分析程序,简易Z评分成像系统(eZIS)和自动定量分析程序3DSRT对SPECT的结果进行了分析。结果:使用eZIS进行的定性分析显示17位受试者(68%)的枕叶灌注不足。在3DSRT模板上枕骨节段的定量平均血流灌注为40.7 +/- 5.03 ml / 100 g / min(右)和40.5 +/- 5.38 ml / 100 g / min(左),在19名DLB患者中值低于正常极限。 25名受试者中有24名(96%)在延迟图像中心脏MIBG摄取降低。结论:MIBG心肌闪烁显像在检测DLB的特征方面优于脑灌注SPECT。我们的结果表明,结合SPECT和MIBG闪烁显像可以提高DLB临床诊断的准确性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号