...
首页> 外文期刊>Journal of diabetes investigation. >Continuous glucose monitoring system: Is it really accurate, safe and clinically useful?
【24h】

Continuous glucose monitoring system: Is it really accurate, safe and clinically useful?

机译:连续葡萄糖监测系统:它真的准确,安全并且在临床上有用吗?

获取原文
获取原文并翻译 | 示例
           

摘要

The continuous glucose monitoring system (CGM) has been used for constant checking of glucose level by measuring interstitial glucose concentrations, since the early days of the 21st century. It can potentially improve diabetes care if used carefully with the understanding of the characteristics of this system. Although there is a time lag of approximately 5-15min between blood and interstitial glucose levels, the system is considered the most suitable device for meticulous glucose control and prevention of hypoglycemia. A large number of studies have examined its accuracy, safety and clinical effectiveness. The continuous glucose-error grid analysis (CG-EGA), designed by WL Clarke, evaluates the clinical accuracy of CGM. It examines 'temporal' characteristics of the data, analyzing pairs of reference and sensor readings as a process in time represented by a 'bidimensional' time series and taking into account inherent physiological time lags. Investment in CG-EGA is clearly meaningful, even though there are other methodologies for evaluation. The use of each method complementarily is the most effective way to prove the accuracy of the device. The device has improved gradually, and real-time CGM, which allows real-time monitoring of blood glucose level, is already available commercially. The use of real-time CGM could potentially lead to over- or undertreatment with insulin. Patient education through proper and effective handling of the new device is essential to improve diabetes care.
机译:自21世纪初期以来,连续血糖监测系统(CGM)已用于通过测量组织间葡萄糖浓度来持续检查血糖水平。如果在了解该系统特性的前提下谨慎使用,它可能会改善糖尿病护理。尽管血液和间质葡萄糖水平之间存在大约5-15分钟的时间滞后,但该系统仍被认为是最适合精确控制血糖和预防低血糖的设备。大量研究检查了其准确性,安全性和临床有效性。 WL Clarke设计的连续葡萄糖误差网格分析(CG-EGA)评估了CGM的临床准确性。它检查数据的“时间”特性,以“二维”时间序列表示的时间过程分析参考和传感器读数对,并考虑固有的生理时滞。尽管还有其他评估方法,但对CG-EGA的投资显然是有意义的。互补地使用每种方法是证明设备精度的最有效方法。该设备已逐渐得到改善,并且可以实时监测血糖水平的实时CGM已在市场上销售。使用实时CGM可能会导致胰岛素治疗过度或治疗不足。通过正确有效地使用新设备进行患者教育对于改善糖尿病护理至关重要。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号