首页> 外文期刊>Journal of environmental monitoring: JEM >Speciation of nickel in airborne particulate matter by means of sequential extraction in a micro flow system and determination by graphite furnace atomic absorption spectrometry and inductively coupled plasma mass spectrometry
【24h】

Speciation of nickel in airborne particulate matter by means of sequential extraction in a micro flow system and determination by graphite furnace atomic absorption spectrometry and inductively coupled plasma mass spectrometry

机译:通过微流系统中的连续萃取并通过石墨炉原子吸收光谱法和感应耦合等离子体质谱法测定空气中颗粒物中镍的形态

获取原文
获取原文并翻译 | 示例
           

摘要

A four-stage sequential extraction procedure for the speciation of nickel has been applied to ambient aerosol samples. The determination of the soluble, sulfidic, metallic and oxidic Ni fractions in particulate matter was carried out by graphite furnace (electrothermal) atomic absorption spectrometry (ETAAS) and inductively coupled plasma mass spectrometry (ICP-MS). An EDTA solution, a mixture of diammonium citrate and hydrogen peroxide, and a KCuCl_3 solution were used as leaching agents for the determination of the soluble, sulfidic and metallic species, respectively, and nitric acid was used for the determination of oxidic compounds after microwave digestion of particulate matter sampled on filters. A new micro scale filter holder placed in a closed flow injection analysis (FIA) system for use in nickel speciation by means of sequential extraction, and the results of the optimisation of the extraction conditions are described. The temperature program for ETAAS was optimised for all extraction solutions with the aid of temperature curves. Pyrolysis temperatures of 900, 600 and 1000 ℃ were found to be optimum for EDTA, hydrogen peroxide plus ammonium citrate and KCuCl_3-containing solutions, respectively. Airborne dust was sampled on filters at two locations near to a metallurgical plant in Dortmund, Germany. Concentrations in the low n m~(-3) range down to the detections limits (0.1-0.3 ng m~(-3)) and various nickel species were found to be present in the collected dust. The mean fractions of total nickel (sampling period of one month) were found to contain 36±20% of soluble, 6±4% of sulfidic, 11±15% of metallic and 48±18% of oxidic nickel.
机译:用于镍形态分析的四阶段顺序萃取程序已应用于环境气溶胶样品。用石墨炉(电热)原子吸收光谱法(ETAAS)和电感耦合等离子体质谱法(ICP-MS)测定颗粒物中的可溶性,硫化物,金属和氧化镍含量。 EDTA溶液,柠檬酸二铵和过氧化氢的混合物以及KCuCl_3溶液分别用作溶出剂,用于测定可溶性,硫化物和金属种类,而硝酸用于微波消解后的氧化性测定。过滤器上采样的颗粒物的数量。介绍了一种新的微型过滤器支架,该支架放置在封闭流动注射分析(FIA)系统中,用于通过顺序萃取进行镍形态分析,并描述了萃取条件的优化结果。借助温度曲线,针对所有萃取溶液优化了ETAAS的温度程序。发现EDTA,过氧化氢,柠檬酸铵和含KCuCl_3的溶液的最佳热解温度分别为900、600和1000℃。在德国多特蒙德一家冶金厂附近的两个位置的过滤器上采样了空气中的灰尘。低n m〜(-3)范围内的浓度低至检测极限(0.1-0.3 ng m〜(-3)),并且在收集的粉尘中发现了各种镍。发现总镍的平均分数(一个月的采样期)包含36±20%的可溶性镍,6±4%的硫,11±15%的金属和48±18%的氧化镍。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号