首页> 外文期刊>Journal of Endodontics: Official Journal of American Association of Endodontists >Uncontrolled Removal of Dentin during In Vitro Ultrasonic Irrigant Activation in Curved Root Canals
【24h】

Uncontrolled Removal of Dentin during In Vitro Ultrasonic Irrigant Activation in Curved Root Canals

机译:弯曲根管体外超声冲洗活化过程中无法控制的牙本质去除

获取原文
获取原文并翻译 | 示例
       

摘要

Introduction: The aim of this study was to examine the effect of file type and activation time on the uncontrolled removal of dentin during in vitro ultrasonic irrigant activation in prepared curved root canals. Methods: Seventy-two curved mesial root canals of human mandibular molars were prepared to size 35/.04 taper. The specimens were randomly allocated to 4 groups (n = 18). Two milliliters of 2% sodium hypochlorite were delivered 3 times to each root canal, and the irrigant was ultrasonically activated every time for 10 seconds at 35% power either by a ultrasonic K-file (group A), an Irrisafe file (Acteon Satelec, Merignac, France) (group B), or a smooth wire (group C). The same specimens also received further activation continuously for another 30 seconds. No activation took place in group D. Specimens were scanned by micro computed tomographic imaging before and after preparation and after the first and second activation period. Scans were coregistered and segmented, and the amount of dentin removed during activation was quantified by morphological operations. Results were analyzed by nonparametric statistical tests (alpha = 0.05). Results: Defects with a maximum depth of 0.18 mm were identified. Both the type of file and activation time affected the removal of dentin (P <= .002 and P <= .031, respectively). K-files removed more dentin than Irrisafe files and smooth wires in the coronal and middle third. All files removed comparable amounts in the apical third. Conclusions: All 3 types of files may result in uncontrolled removal of dentin. A longer activation time may increase this effect.
机译:简介:这项研究的目的是检查在准备好的弯曲根管中进行体外超声冲洗活化过程中,文件类型和活化时间对无法控制的牙本质去除的影响。方法:准备人牙磨牙的72条弯曲的近中牙根管,锥度为35 / .04。将标本随机分为4组(n = 18)。将2毫升2%的次氯酸钠分3次输送到每个根管,并通过超声K型锉(A组),Irrisafe锉(Acteon Satelec,法国Merignac)(B组),或光滑的线材(C组)。相同的样本还连续30秒继续受到进一步激活。在D组中没有发生活化。在制备之前和之后以及在第一和第二活化期之后通过显微计算机断层摄影术扫描样品。扫描共配准和分段,并通过形态学操作量化活化过程中去除的牙本质的量。通过非参数统计检验分析结果(α= 0.05)。结果:鉴定出最大深度为0.18 mm的缺陷。文件的类型和激活时间都会影响牙本质的去除(分别为P <= .002和P <= .031)。与Irrisafe文件相比,K锉去除了更多的牙本质,并在冠状和中间三分之一处去除了光滑的金属丝。所有文件删除了可比数量的顶端。结论:所有3种类型的文件都可能导致无法控制的牙本质去除。较长的激活时间可能会增加这种效果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号