首页> 外文期刊>Journal of Endodontics: Official Journal of American Association of Endodontists >An Ex Vivo Comparison of Diagnostic Accuracy of Cone-beam Computed Tomography and Periapical Radiography in the Detection of Furcal Perforations
【24h】

An Ex Vivo Comparison of Diagnostic Accuracy of Cone-beam Computed Tomography and Periapical Radiography in the Detection of Furcal Perforations

机译:锥形束计算机断层扫描和根尖X线摄影在皮瓣穿孔检测中的诊断准确性的体外比较

获取原文
获取原文并翻译 | 示例
       

摘要

Introduction: The purpose of this study was to assess cone-beam computed tomographic (CBCT) imaging with different voxel sizes and an intraoral sensor in the detection of furcation perforations. Methods: In 40 teeth, furcation perforations were created, and 40 intact teeth served as the control. Five image sets were obtained: (1) CBCT, 0.1 mm(3) voxel size; (2) CBCT, 0.15 mm(3) voxel size; (3) CBCT, 0.2 mm(3) voxel size; (4) CBCT, 0.4 mm(3) voxel size; and (5) digital periapical images. Images were evaluated twice by 3 observers. Perforation widths were measured by CBCT software. Receiver operating characteristic analysis was used to assess the observers' ability to detect perforation, and area under the curve values were compared by using t tests, with a significance level of alpha = 0.05. Results: No differences (P > .05) were found between any of the median area under the curve and true positive rate values obtained with different CBCT voxel sizes. Actual perforation width correlated highly with CBCT width measurements. Conclusions: Low-resolution CBCT imaging can be preferred for furcation perforation diagnosis because of its low dose and reliable diagnostic outcome.
机译:引言:这项研究的目的是评估具有不同体素大小的锥形束计算机断层扫描(CBCT)成像以及口腔内传感器在分叉穿孔检测中的作用。方法:在40颗牙齿中产生分叉穿孔,并以40颗完整牙齿作为对照。获得了五个图像集:(1)CBCT,0.1 mm(3)体素大小; (2)CBCT,0.15毫米(3)体素尺寸; (3)CBCT,0.2毫米(3)体素尺寸; (4)CBCT,0.4毫米(3)体素尺寸; (5)根尖周数字图像。 3位观察者对图像进行了两次评估。穿孔宽度通过CBCT软件测量。接受者操作特征分析用于评估观察者检测穿孔的能力,并通过t检验比较曲线值下的面积,显着性水平为α= 0.05。结果:曲线下的任何中值面积与使用不同CBCT体素尺寸获得的真实阳性率值之间均未发现差异(P> 0.05)。实际射孔宽度与CBCT宽度测量高度相关。结论:低分辨率CBCT成像因其剂量小且诊断结果可靠而可优选用于分叉穿孔诊断。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号