This study was designed to determine the efficiency of hand and rotary instruments in shaping oval root canals. Seventy-five oval canals were equally divided into three groups. The apical third was prepared with rotary LightSpeed instruments either to size 52.5 (mandibular incisors) or to size 57.5 (distal root of mandibular molars). The middle third with an oval cross-section was shaped with Hedstrom hand files using circumferential technique, with 6% taper rotary Hero files in a circumferential filing movement or with rotary LightSpeed instruments in a step-back technique. Instrumentation was performed under clinical conditions in a phantom head. The teeth were sectioned at two levels in the middle third of the root. An assembly technique allowed comparing the canal outline before and after instrumentation. The photographed root sections were superimposed and traced under a stereomicroscope. The ratio of prepared to unprepared canal outline was calculated for each section. The lowest values were observed in the LightSpeed group (mean: 0.42; 95% confidence interval (CI): 0.37; 0.47). Significantly higher values were recorded in the Hero group (mean: 0.58; 95% CI: 0.53; 0.64) and in the Hedstrom group (mean: 0.56; 95% CI: 0.49; 0.62). No instrumentation technique was capable of completely preparing dentin walls of oval root canals. Circumferential filing of the middle third of oval root canals with either 6% taper Hero files or conventional Hedstrom hand files gave comparable results.
机译:本研究旨在确定手动和旋转器械在塑造椭圆形根管中的效率。将75条椭圆形的运河平均分为三组。用旋转LightSpeed器械将根尖的三分之一准备好,使其尺寸为52.5(下颌切牙)或尺寸为57.5(下颌磨牙的后牙根)。中间三分之一的横截面为椭圆形,使用Hedstrom手锉使用圆周技术成形,使用6%锥形圆锥形Hero锉进行圆周锉移动,或者使用LightSpeed旋转工具进行后退成型。仪器是在临床条件下在幻像头中进行的。牙齿在根的中间三分之一处分为两个级别。组装技术可以比较器械前后的运河轮廓。将拍摄的根部切片叠加并在立体显微镜下追踪。为每个部分计算准备好的与未准备好的运河轮廓之比。在LightSpeed组中观察到最低值(平均值:0.42; 95%置信区间(CI):0.37; 0.47)。 Hero组(平均值:0.58; 95%CI:0.53; 0.64)和Hedstrom组(平均值:0.56; 95%CI:0.49; 0.62)记录到更高的值。没有仪器技术能够完全准备椭圆形根管的牙本质壁。椭圆形根管中段的三分之一采用6%的锥形Hero锉或常规的Hedstrom手工锉进行周向锉锉,结果相近。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号