首页> 外文期刊>Journal of Endodontics: Official Journal of American Association of Endodontists >Sealing ability of mineral trioxide aggregate and super-EBA when used as furcation repair materials: a longitudinal study.
【24h】

Sealing ability of mineral trioxide aggregate and super-EBA when used as furcation repair materials: a longitudinal study.

机译:当用作分叉修复材料时,三氧化物矿物聚集体和超级EBA的密封能力:一项纵向研究。

获取原文
获取原文并翻译 | 示例
       

摘要

Immediate sealing of furcation perforations enhances the repair process. The purpose of this study was to longitudinally compare the ability of mineral trioxide aggregate (MTA) and Super-EBA to seal furcation perforations. Fifty-one extracted human maxillary molars were decoronated 3 mm above the CEJ, and the roots were amputated 3 mm below the furcation. A #2 high-speed round bur was used to perforate the center of the furcations. The canals were obturated with gutta-percha, and the root ends were sealed with C&B Metabond. Three experimental groups of 15 teeth each were restored with MTA, Super-EBA, or a combination of MTA in the perforation and a Super-EBA dome on the pulpal floor. Six teeth served as controls. Each tooth was affixed to a fluid filtration device and subjected to a pressure of 20 cm H2O. The integrity of the perforation seal was evaluated initially at 30 min for the Super-EBA and the combination groups and at 4 h for the MTA group. Additional measurements were then made at 24 h, 1 week, and 1 month. The controls behaved as expected. A two-way ANOVA revealed a significant difference (p = 0.01) between materials. Tukey's test isolated the difference to Super EBA as producing a superior seal but only at 24 h. There was no significant effect with time (p = 0.57) or the interaction of the materials with time (p = 0.66). All materials sealed the perforations very well. The maximum leakage of all materials was <0.007 microL min(-1) cm H2O(-1).
机译:立即密封分叉穿孔可增强修复过程。这项研究的目的是纵向比较三氧化二矿骨料(MTA)和Super-EBA密封分叉穿孔的能力。在CEJ上方3 mm处切除五十一个提取的人类上颌磨牙,在分叉下方3 mm处切除根。使用#2高速圆钻打孔分叉的中心。运河用牙胶充填,根端用C&B Metabond密封。用MTA,Super-EBA或穿孔中的MTA和牙髓基底上的Super-EBA穹顶的组合修复三个实验组,每组15个牙齿。六个牙齿作为对照。将每个牙齿固定在流体过滤装置上,并施加20 cm H2O的压力。对于Super-EBA和组合组,最初在30分钟时评估穿孔密封的完整性,而对于MTA组则在4小时时评估穿孔密封的完整性。然后在24小时,1周和1个月进行其他测量。控件的行为符合预期。双向方差分析显示材料之间存在显着差异(p = 0.01)。 Tukey的测试隔离了与Super EBA的不同之处,即仅在24 h时便产生了优异的密封效果。时间(p = 0.57)或材料与时间的相互作用(p = 0.66)没有显着影响。所有材料都很好地密封了穿孔。所有材料的最大泄漏量为<0.007 microL min(-1)cm H2O(-1)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号