首页> 外文期刊>Journal of Endodontics: Official Journal of American Association of Endodontists >Comparison of the time required to create secondary fracture of separated file fragments by using ultrasonic vibration under various canal conditions
【24h】

Comparison of the time required to create secondary fracture of separated file fragments by using ultrasonic vibration under various canal conditions

机译:比较在各种管道条件下使用超声振动产生分开的锉碎片二次破裂所需的时间

获取原文
获取原文并翻译 | 示例
       

摘要

Introduction Nickel-titanium files often separate because of mechanical fatigue. The purpose of this study was to determine safe preparation techniques for separated file removal by using ultrasonics. Methods Fifty nickel-titanium file fragments were divided into 5 groups. An ultrasonic tip was activated on a file fragment positioned between dentin blocks simulating several canal conditions: Group 1 consisted of the fragment protruding from a pair of straight dentin blocks. For group 2, the fragment was also positioned between 2 straight dentin blocks except one block was positioned 1 mm more apically than the other block, simulating a troughed area that is often created during file removal attempts. For groups 3-5, the fragment was positioned similarly as group 2 but between blocks with 30, 45, and 60 curvatures, respectively. The time it took for secondary fracture to occur was recorded, and the data were statistically analyzed. Results Fragments with dentin wall supporting on the opposite side of ultrasonic activation site resisted fracture significantly longer than those without it. Fragments in 30 and 45 curved blocks took significantly longer to fracture than the other groups (Fisher protected least significant difference, P <.05). Conclusions Secondary fracture of separated files appeared to be reduced when the ultrasonic tip was applied to the inner curvature of the canal.
机译:简介镍钛锉刀经常由于机械疲劳而分开。这项研究的目的是确定使用超声波分离文件的安全准备技术。方法将镍钛锉片五十片分为5组。在模拟几种牙槽管状况的牙本质块之间的锉刀碎片上激活了一个超声尖端:第1组由从一对直齿牙本质块突出的碎片组成。对于第2组,该片段还位于2个笔直的牙本质块之间,但其中一个块的顶端比另一个块高1 mm,模拟了在尝试删除文件时经常会形成的凹陷区域。对于3-5组,该片段的位置与第2组相似,但分别位于具有30、45和60个曲率的块之间。记录发生继发性骨折所需的时间,并对数据进行统计分析。结果在超声激活部位的另一侧支撑牙本质壁的碎片比没有碎片的碎片抵抗骨折的时间长得多。 30和45个弯曲块中的碎片断裂所花的时间比其他组要长得多(Fisher保护的差异不显着,P <.05)。结论当超声尖端应用于根管内曲率时,分离锉的继发骨折似乎有所减少。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号