INTRODUCTION: Obtaining a correct working length is critical to the success of endodontic therapy. The aim of this clinical study was to compare the effect of working length determination using electronic apex locator or working length radiograph on the length adequacy of final working length as well as the final obturation. METHODS: A total of 84 patients with 188 canals were randomized into two groups; in group 1, the working length was determined by working length radiograph, whereas in group 2, it was determined by the Raypex5 electronic apex locator (VDW, Munich, Germany). Length adequacy was assessed in each group for master cone and final obturation radiography and categorized into short, acceptable, and over cases. RESULTS: There was no statistically significant difference between the rates of acceptable (master cone radiography: group 1 = 82.1% and group 2 = 90.4%; final radiography: group 1 = 85.7% and group 2 = 90.4%) and short cases (master cone radiography: group 1 = 7.1% and group 2 = 8.7%; final radiography: group 1 = 1.2% and group 2 = 1%) between the two groups. Over cases in master cone radiography were significantly more in group 1 (10.7%) than group 2 (1%) (chi(2), p = 0.00). However, this category did not show a significant difference for final obturation between group 1 (13.1%) and group 2 (8.7%). CONCLUSION: The results of endodontic treatment using the Raypex5 electronic apex locator are quite comparable, if not superior, to radiographic length measurement regarding the rates of acceptable and short cases. Furthermore, in addition to reducing the radiographic exposure, electronic apex locators are superior in reducing overestimation of the root canal length.
机译:简介:获得正确的工作长度对于牙髓治疗的成功至关重要。这项临床研究的目的是比较使用电子根尖定位仪或工作长度X线摄片机确定工作长度对最终工作长度以及最终阻塞长度的影响。方法:将84例患者的188条运河随机分为两组。在第1组中,工作长度由工作长度射线照片确定,而在第2组中,由Raypex5电子顶点定位器(VDW,慕尼黑,德国)确定。评估每个组的主锥和最终闭孔放射线照相术的长度适当性,并分为短期,可接受和过度病例。结果:合格率(主锥X线照相:第1组= 82.1%和第2组= 90.4%;最终X线照相:第1组= 85.7%和第2组= 90.4%)和短病例(主锥形照相:第1组= 7.1%,第2组= 8.7%;最终X射线照相:两组之间的第1组= 1.2%,第2组= 1%。第1组(10.7%)比第2组(1%)的主锥X线检查病例多(chi(2),p = 0.00)。但是,该类别在第一组(13.1%)和第二组(8.7%)之间的最终闭锁方面没有显着差异。结论:使用Raypex5电子根尖定位仪进行牙髓治疗的结果在可接受和较短病例的发生率方面与放射线长度测量相当,甚至不是相当。此外,除了减少射线照相曝光外,电子根尖定位器在减少高估根管长度方面也很出色。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号