首页> 外文期刊>Journal of endovascular therapy: an official journal of the International Society of Endovascular Specialists >Changes in coronary flow reserve following stent implantation in the swine descending thoracic aorta.
【24h】

Changes in coronary flow reserve following stent implantation in the swine descending thoracic aorta.

机译:在猪降主动脉支架植入后冠状动脉血流储备的变化。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: To evaluate coronary flow reserve (CFR) changes following stent implantation in the descending thoracic aorta (DTA) of a porcine model. METHODS: Six pigs (3 males; 40 to 44 kg) were anesthetized and kept on mechanical ventilation. A 6-F guiding right Judkins catheter was advanced under fluoroscopy to the right coronary artery, and a pressure wire with a temperature sensor was placed within the vessel lumen at a distance of 4 cm from the ostium. CFR was estimated by the thermodilution method before and after maximal coronary vasodilation with 20 mg of intracoronary papaverine. Aortography was also performed to measure aortic diameter. Subsequently, a self-expanding vascular stent was deployed into the DTA just below the left subclavian artery (LSA), and CFR was measured again. All animals were maintained for 3 weeks; at the end of this period, a further CFR was calculated using the same procedure. RESULTS: The mean aortic diameter below the LSA was 12.15+/-0.15 mm. Following stent deployment, the mean aortic diameter measured at the stented segment was 12.58+/-0.11 (p=0.001 versus baseline). The mean CFR value was 4.70+/-2.00 before stent implantation, 2.68+/-0.86 immediately after, and 4.05+/-1.15 at 3 weeks after stenting. Accordingly, CFR values were significantly depressed immediately after stent placement compared with baseline (p=0.027). However, CFR values obtained 3 weeks following stent deployment were similar to the initial values (p=0.59). CONCLUSION: Stent deployment in the normal swine DTA produces a significant immediate decrease in CFR, which is attenuated 3 weeks later. The clinical impact of CFR changes following DTA endografting remain to be elucidated.
机译:目的:评估猪模型降主动脉(DTA)支架植入后冠状动脉血流储备(CFR)的变化。方法:将六头猪(3头雄性; 40至44千克)麻醉并保持机械通气。在荧光透视下,将6-F引导的右Judkins导管推进到右冠状动脉,并将带有温度传感器的压力线放置在距腔口4 cm的血管腔内。在20 mg冠状动脉内罂粟碱最大冠脉扩张之前和之后,通过热稀释法估算CFR。还进行了主动脉造影以测量主动脉直径。随后,在左锁骨下动脉(LSA)下方的DTA中放置一个自扩张式血管支架,并再次测量CFR。所有动物维持3周。在此期间结束时,使用相同的程序进一步计算CFR。结果:LSA下方的平均主动脉直径为12.15 +/- 0.15 mm。支架展开后,在支架段测得的平均主动脉直径为12.58 +/- 0.11(相对于基线,p = 0.001)。支架植入前的平均CFR值为4.70 +/- 2.00,支架植入后立即为2.68 +/- 0.86,支架植入后3周为4.05 +/- 1.15。因此,与基线相比,支架置入后立即显着降低了CFR值(p = 0.027)。但是,支架植入后3周获得的CFR值与初始值相似(p = 0.59)。结论:正常猪DTA中的支架部署会导致CFR立即显着下降,并在3周后减弱。 DTA内移植后CFR变化的临床影响尚待阐明。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号