Ventana fenestrated stent-graft system for endovascular repair of juxtarenal aortic aneurysms

机译:Ventana开窗式带支架系统用于近侧主动脉瘤的血管内修复

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Purpose: To describe the initial use of an off-the-shelf fenestrated stent-graft system for endovascular repair of juxtarenal abdominal aortic aneurysms. Technique: The off-the-shelf Ventana fenestrated stent-graft system consists of a 25-mm IntuiTrak self-expanding bifurcated stent-graft implanted at the aortic bifurcation. A Ventana self-expanding fenestrated proximal extension stent-graft is overlapped with the bifurcated body distally and sealed proximally in the visceral segment with a 4-cm-long scallop below and around the SMA and celiac artery, obviating the need for an infrarenal neck. Movable, non-reinforced, 3-mm fenestrations for the renal arteries can be expanded to 10 mm. The 22-F delivery system includes 6.5-F guide sheaths pre-inserted through the stent-graft fenestrations so that the renal arteries are cannulated before the fenestrated stent-graft is deployed. The Xpand renal stent-grafts, with a proximal segment intended for flaring in the aorta, are delivered on 5-F or 6-F balloon catheters through the 6.5-F guide sheaths. The technique is illustrated in 2 patients (76 and 77 years of age) with significant comorbidities and juxtarenal aortic aneurysms measuring 5.9 and 7.4 mm, respectively, who were enrolled in an ongoing prospective trial (www.ClinicalTrials.gov identifier NCT01348828) of this new device. Patient 1 had a 28-mm fenestrated stent-graft system with the aligned fenestration configuration deployed, while the stent-graft in Patient 2 was 32 mm in diameter and had offset fenestrations to accommodate the renal artery geometry. Mean fluoroscopy times were 27 and 35 minutes, and the contrast volumes were 72 and 67 mL. Total procedure times were 84 and 71 minutes. The aneurysms were effectively excluded in uneventful procedures, with no migration, endoleak, or renal dysfunction at 6-month follow-up. Conclusion: There exists an unmet clinical need for a broadly applicable endovascular option for repair of more complex juxtarenal or pararenal aortic aneurysms. These cases suggest that endovascular repair of such aneurysms using the Ventana fully integrated off-the-shelf stent-graft system is safe and feasible.
机译:目的:描述现成的开窗支架移植物系统在近侧腹主动脉瘤的血管内修复中的初步应用。技术:现成的Ventana开窗式支架移植物系统由在主动脉分叉处植入的25毫米IntuiTrak自扩张分叉式支架移植物组成。将Ventana自膨式有孔的近端延伸支架移植物与分叉的身体向远端重叠,并在内脏段中向近端密封,在SMA和腹腔动脉下方和周围有一个4厘米长的扇贝,从而消除了对肾下颈的需求。可移动的非增强型3毫米肾动脉开窗可扩展至10毫米。 22 F输送系统包括通过支架移植窗预先插入的6.5 F引导鞘,以便在部署带窗支架移植物之前先将肾动脉插管。 Xpand肾支架移植物具有近端节段,用于在主动脉中张开,通过6.5-F引导鞘通过5-F或6-F球囊导管输送。这项技术在2例分别患有严重合并症和近端主动脉瘤的患者(年龄分别为5.9和7.4毫米)中进行了说明(该患者参加了一项正在进行的这项新的正在进行的前瞻性试验(www.ClinicalTrials.gov标识符NCT01348828))。设备。患者1具有28毫米的带窗开孔支架植入物系统,并部署了对准的开窗构形,而患者2的支架植入物直径为32毫米,并且开窗孔偏移以适应肾动脉的几何形状。透视的平均时间为27和35分钟,造影剂体积为72和67 mL。整个过程时间分别为84分钟和71分钟。在6个月的随访中,无畸形的程序有效地排除了动脉瘤,没有迁移,内渗或肾功能不全。结论:目前尚无临床上需要广泛应用的血管内治疗方案来修复更复杂的近肾或肾旁主动脉瘤。这些案例表明,使用Ventana完全集成的现成支架移植系统对此类动脉瘤进行血管内修复是安全可行的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号