PURPOSE: To report a technical modification that will prevent sheath kinking in acutely angled vessels during carotid stent placement. TECHNIQUE: If a long vascular sheath kinks when engaging an acutely angled common carotid or innominate artery, the sheath is pulled caudally approximately 2 cm while a 0.014-inch guidewire, supported by a coronary balloon catheter, is advanced toward the internal carotid artery (ICA). Alternatively, to avoid kinking, the original 0.035-inch super stiff wire is maintained within the sheath until the 0.014-inch wire and coronary balloon have exited the sheath's distal tip. CONCLUSIONS: If an aortic arch is tortuous and the angle of the common carotid artery is unfavorable, a guiding catheter is preferable to a long vascular sheath for accessing the ICA during carotid stent procedures.
机译:目的:报告一项技术改进,以防止在放置颈动脉支架期间锐角血管中的护套扭结。技术:如果在与锐角的颈总动脉或无名动脉接合时长的血管鞘扭结,则将尾鞘牵拉约2 cm,而由冠状动脉球囊导管支撑的0.014英寸导丝向颈内动脉(ICA)前进)。或者,为避免扭结,将原始的0.035英寸超硬金属丝保持在护套内,直到0.014英寸的金属丝和冠状动脉球囊退出护套的远端为止。结论:如果主动脉弓弯曲且颈总动脉角度不利,则在颈动脉支架置入过程中,导管比长血管鞘更可取。