首页> 外文期刊>Journal of endovascular therapy: an official journal of the International Society of Endovascular Specialists >Roentgen stereophotogrammetric analysis: an accurate tool to assess stent-graft migration.
【24h】

Roentgen stereophotogrammetric analysis: an accurate tool to assess stent-graft migration.

机译:伦琴立体摄影测量分析:评估支架-移植物迁移的准确工具。

获取原文
获取原文并翻译 | 示例
       

摘要

PURPOSE: To evaluate in an in vitro model the feasibility and accuracy of Roentgen stereophotogrammetric analysis (RSA) versus computed tomography (CT) for the ability to detect stent-graft migration. METHODS: An aortic model was constructed from a 22-mm-diameter Plexiglas tube with 6-mm polytetrafluoroethylene inlays to mimic the renal arteries. Six tantalum markers were placed in the wall of the aortic tube proximal to the renal arteries. Another 6 markers were added to a Gianturco stent, which was cast in Plexiglas and placed inside the aorta and fixed to a micromanipulator to precisely control displacement of the stent along the longitudinal axis. Sixteen migrations were analyzed with RSA software and compared to the micromanipulator. Thirty-two migrations were measured by 3 observers from CT images acquired with 16x0.5-mm beam collimation and reconstructed with a 0.5-mm slice thickness and a 0.4-mm reconstruction interval. Measurements were made with Vitrea postprocessing software using a standardclinical protocol and central lumen line reconstruction. Results of CT were also compared to the micromanipulator. RESULTS: The mean RSA measurement error compared to the micromanipulator was 0.002+/-0.044 mm, and the maximum error was 0.10 mm. There was no statistically significant interobserver variability for CT (p=0.17). The pooled mean (maximum) measurement error of CT was 0.14+/-0.29 (1.00) mm, which was significantly different from the RSA measurement error (p<0.0001). CONCLUSION: Detection of endograft migration by RSA is feasible and was significantly more accurate than CT in this nonpulsatile in vitro model.
机译:目的:在体外模型中评估伦琴立体摄影测量分析(RSA)相对于计算机断层摄影(CT)的可行性和准确性,以检测支架移植物迁移的能力。方法:用直径22毫米的Plexiglas管和6毫米的聚四氟乙烯嵌体构建主动脉模型,以模拟肾动脉。六个钽标记放置在靠近肾动脉的主动脉管壁中。将另外6种标记物添加到Gianturco支架中,该支架在Plexiglas中浇铸并放置在主动脉内,并固定到微操纵器上,以精确控制支架沿纵轴的位移。使用RSA软件分析了16种迁移,并与微操纵器进行了比较。 3位观察者从16x0.5mm光束准直采集的CT图像中测量了32个偏移,并以0.5mm的切片厚度和0.4mm的重建间隔对其进行了重建。使用标准临床方案和中央管腔线重建,使用Vitrea后处理软件进行测量。还将CT结果与微操纵器进行了比较。结果:与微操作器相比,平均RSA测量误差为0.002 +/- 0.044 mm,最大误差为0.10 mm。 CT的观察者间差异无统计学意义(p = 0.17)。 CT的合并平均(最大)测量误差为0.14 +/- 0.29(1.00)mm,与RSA测量误差显着不同(p <0.0001)。结论:在这种非搏动性体外模型中,通过RSA检测内移植物的迁移是可行的,并且比CT准确得多。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号