首页> 外文期刊>Journal of endovascular therapy: an official journal of the International Society of Endovascular Specialists >A biodegradable stent based on poly(L-lactide) and poly(4-hydroxybutyrate) for peripheral vascular application: preliminary experience in the pig.
【24h】

A biodegradable stent based on poly(L-lactide) and poly(4-hydroxybutyrate) for peripheral vascular application: preliminary experience in the pig.

机译:基于聚(L-丙交酯)和聚(4-羟基丁酸酯)的可生物降解支架,用于外周血管的应用:在猪中的初步经验。

获取原文
获取原文并翻译 | 示例
       

摘要

PURPOSE: To assess the technical feasibility and biocompatibility of a novel stent based on poly(L-lactide) (PLLA) and poly(4-hydroxybutyrate) (P4HB) for peripheral vascular applications. METHODS: A polytetrafluoroethylene aortobi-iliac graft was implanted in 5 pigs through a midline abdominal incision. After transverse graft limb incision, 5 PLLA/P4HB stents and 5 metal stents (316L stainless steel) were randomly deployed at both iliac anastomotic sites with 6-mm balloon catheters. Angiography was performed to determine patency prior to sacrifice at 6 weeks. Stented segments were surgically explanted and processed for quantitative histomorphometry. Vascular injury and inflammation scores were assigned to the stented iliac segments. RESULTS: No animals were lost during follow-up. All PLLA/P4HB stents were deployed within 2 minutes by balloon inflation to 8 bars without rupture of the stent struts or anastomotic suture. All stents were patent on postprocedural angiography. Histological analysis showed no signs of excessive recoiling or collapse. PLLA/P4HB stents demonstrated decreased residual lumen area and increased neointimal area after 6 weeks (12.27+/-0.62 and 8.40+/-1.03 mm(2), respectively) compared to 316L stents (13.54+/-0.84 and 6.90+/-1.11 mm(2), respectively) as the result of differences in stent areas (PLLA/P4HB: 4.31+/-0.15 mm(2); 316L: 2.73+/-0.29 mm(2)). Vascular injury scores showed only mild vascular trauma for all stents (PLLA/P4HB: 0.41+/-0.59; 316L: 0.32+/-0.47). Inflammatory reaction was slightly higher around PLLA/P4HB stent struts (1.39+/-0.52) compared to 316L (1.09+/-0.50). CONCLUSION: Rapid balloon expansion of PLLA/P4HB stents is feasible without risk of strut rupture. PLLA/P4HB stents provide adequate mechanical stability after iliac anastomotic stenting in pigs. Smaller residual luminal areas in the PLLA/P4HB stents might have been caused by tissue ingrowth into the larger strut interspaces due to higher strut thickness (stent area) in this group. This limitation needs to be addressed in future work on the stent design.
机译:目的:评估基于聚(L-丙交酯)(PLLA)和聚(4-羟基丁酸酯)(P4HB)的新型支架在外周血管应用中的技术可行性和生物相容性。方法:通过腹部中线切口将5只猪植入聚四氟乙烯主动脉-骨移植物。横切移植肢体后,用6毫米球囊导管将5个PLLA / P4HB支架和5个金属支架(316L不锈钢)随机部署在两个an吻合部位。在第6周处死之前进行血管造影术以确定通畅性。手术切除支架段并进行定量组织形态测定。将血管损伤和炎症评分分配给带支架的段。结果:在随访期间没有动物丢失。所有PLLA / P4HB支架均在2分钟内通过球囊充气展开至8 bar,而没有支架撑杆或吻合口缝合破裂。所有支架均在术后血管造影方面获得专利。组织学分析显示没有过度回卷或塌陷的迹象。与316L支架(13.54 +/- 0.84和6.90 +/-)相比,PLLA / P4HB支架在6周后表现出的残余内腔面积减少,新内膜面积增加(分别为12.27 +/- 0.62和8.40 +/- 1.03 mm(2))。 1.11 mm(2),分别是支架面积差异的结果(PLLA / P4HB:4.31 +/- 0.15 mm(2); 316L:2.73 +/- 0.29 mm(2))。血管损伤评分显示,所有支架均仅受到轻度血管损伤(PLLA / P4HB:0.41 +/- 0.59; 316L:0.32 +/- 0.47)。与316L(1.09 +/- 0.50)相比,PLLA / P4HB支架支杆周围的炎症反应稍高(1.39 +/- 0.52)。结论:PLLA / P4HB支架的快速球囊扩张是可行的,并且没有支柱破裂的风险。 PLLA / P4HB支架在猪肠吻合支架后提供足够的机械稳定性。 PLLA / P4HB支架中较小的腔内残留面积可能是由于该组中较高的支撑杆厚度(支架面积)导致组织向内生长进入较大的支撑杆间隙所致。在以后的支架设计工作中需要解决这个限制。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号