BACKGROUND AND PURPOSE: As endourology becomes an important part of the practice of urology, the use of fluoroscopic guidance has increased the exposure of urologists to the possibly deleterious effects of radiation. There is a need for a method of radiation protection for percutaneous nephrolithotomy (PCNL), as the exposure from radiation scatter may be significant, depending on the difficulty of establishing access. PATIENTS AND METHODS: We ascertained the effectiveness of a newly modified radiation shield during PCNL. Exposure readings were taken using a thermoluminescent dose monitor placed different distances from the radiation source during six PCNLs. We compared the exposure readings with and without the shield. RESULTS: The shield was able to reduce the radiation by an average of 96.1% at a distance of 25 cm and 71.2% at a distance of 50 cm from the source. CONCLUSION: The shield can be used as one step toward the goal of reducing surgeon radiation exposure. Other methods, such as dose-minimizing imaging protocols and adaptation of equipment optimized to reduce exposure, are also important measures in creating a safe environment for both the urologist and the patient.
机译:背景与目的:随着泌尿外科成为泌尿外科实践的重要组成部分,荧光透视引导的使用增加了泌尿科医师对放射线可能造成的有害影响的风险。需要一种用于经皮肾镜取石术(PCNL)的辐射防护方法,因为根据建立通路的难度,来自辐射散射的暴露可能很重要。患者与方法:我们确定了PCNL期间新改良的辐射防护屏的有效性。使用热辐射剂量监测仪在六个PCNL期间与辐射源的距离不同,以获取曝光读数。我们比较了有屏蔽罩和无屏蔽罩的曝光读数。结果:该屏蔽罩能够在距源25厘米处平均减少96.1%的辐射,并在距源50厘米处减少71.2%的辐射。结论:该防护罩可以用作减少外科医生辐射暴露目标的一步。其他方法,例如最小化剂量的成像方案和优化设备以减少暴露,也是为泌尿科医师和患者创造安全环境的重要措施。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号