INTRODUCTION AND OBJECTIVES: Cryoablation is a viable minimally invasive strategy for the treatment of small renal masses. One of the most common postoperative complaints is pain or paresthesia at the cryoprobe insertion site. The use of a 14-gauge angiocatheter to insulate the flank during renal cryotherapy was investigated. MATERIALS AND METHODS: Six Yorkshire swine underwent laparoscopy-guided percutaneous cryoablation of the upper and lower poles of both kidneys with a 1.47 mm (17 gauge) cryoneedle. Treatment consisted of a double 10-minute freeze separated by a 5-minute active thaw. Trials were randomized to placement of the cryoneedle directly through the flank or through a 14-gauge angiocatheter as an insulating sheath. Temperatures were recorded adjacent to the cryoneedle at two depths in the flank with a Multi-Point Thermal Sensor. RESULTS: Twelve trials were completed each with a bare and sheathed cryoneedle. The coldest temperature observed was -26 degrees C for the bare cryoneedle and -21 degrees C for the sheathed cryoneedle. At the outer sensor, there was a 4.1 degrees C increase in mean temperature for freeze 1, and 6.2 degrees C increase in mean temperature for freeze 2 with sheath use. At the inner sensor, there was a 3.0 degrees C increase in mean temperature for freeze 1, and 9.4 degrees C increase in mean temperature for freeze 2 with sheath use. There was a trend toward statistical significance of sheath insulation at the outer (p = 0.07) and inner (p = 0.08) temperature sensors. CONCLUSIONS: A 14-gauge angiocatheter may provide some insulation and thereby might help protect against "ice burn" during renal cryotherapy.
机译:简介和目的:冷冻消融是一种可行的微创治疗小肾脏肿块的策略。术后最常见的不适之一是冷冻探针插入部位的疼痛或感觉异常。研究了在肾脏冷冻治疗过程中使用14号血管导管对侧面进行绝缘的情况。材料与方法:对六只约克郡猪进行了腹腔镜引导下的1.47毫米(17口径)冰冻双肾经皮冷冻消融术。处理包括两次两次10分钟的冷冻和5分钟的主动解冻。试验被随机分配为直接通过侧面或通过14口径的血管导管作为绝缘护套放置冷冻针。使用Multi-Point Thermal Sensor在侧面的两个深度处,在靠近Cryoneedle的位置记录温度。结果:完成了十二项试验,每项试验均使用裸露的带护套的冷冻针。裸露的冷却针观察到的最冷温度为-26摄氏度,带护套的冷却针观察到的最冷温度为-21摄氏度。在外部传感器处,使用护套时,冷冻1的平均温度升高4.1摄氏度,冷冻2的平均温度升高6.2摄氏度。在内部传感器处,使用护套时,冷冻1的平均温度升高3.0摄氏度,冷冻2的平均温度升高9.4摄氏度。在外部温度传感器(p = 0.07)和内部温度传感器(p = 0.08)处,护套绝缘具有统计学意义的趋势。结论:14号血管导管可以提供一些绝缘,从而有助于在肾脏冷冻治疗期间防止“冰灼”。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号