首页> 外文期刊>Journal of endovascular therapy: an official journal of the International Society of Endovascular Specialists >Accurate detection of stent-graft migration in a pulsatile aortic model using Roentgen stereophotogrammetric analysis.
【24h】

Accurate detection of stent-graft migration in a pulsatile aortic model using Roentgen stereophotogrammetric analysis.

机译:使用Roentgen立体摄影测量分析在脉动主动脉模型中准确检测支架-移植物的迁移。

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

PURPOSE: To evaluate the feasibility and accuracy of Roentgen stereophotogrammetric analysis (RSA) versus computed tomography (CT) for detecting stent-graft migration in an in vitro pulsatile circulation model and to study the feasibility of a nitinol endovascular clip (NEC) as an aortic wall reference marker for RSA. METHODS: An aortic model with stent-graft was constructed and connected to an artificial circulation with a physiological flow and pressure profile. Tantalum markers and NECs were used as aortic reference markers for RSA analysis. Stent-graft migrations were measured during pulsatile circulation with RSA and CT. CT images acquired with 64 x 0.5-mm beam collimation were analyzed with Vitrea postprocessing software using a standard clinical protocol and central lumen line reconstruction. RSA in the model with the circulation switched off was used as the reference standard to determine stent-graft migration. The measurement errors of RSA and CT were determined during pulsatile circulation. RESULTS: The mean measurement error +/- standard deviation (maximum) of RSA during pulsatile circulation using the tantalum markers was -0.5+/-0.16 (0.7) mm. Using the NEC, the mean (maximum) measurement error was -0.4+/-0.25 (1.1) mm. The mean (maximum) measurement error of CT was -1.1+/-1.17 (2.8) mm. CONCLUSION: RSA is an accurate and feasible tool to measure stent-graft migration in a pulsatile environment. Migration measurement with RSA was more accurate than CT in this experimental setup. The nitinol clip tested in this study is potentially feasible as an aortic reference marker in patients after endovascular repair.
机译:目的:评估伦琴立体摄影测量分析(RSA)与计算机断层扫描(CT)在体外脉动循环模型中检测支架-移植物迁移的可行性和准确性,并研究镍钛诺血管内夹钳(NEC)作为主动脉的可行性RSA的墙参考标记。方法:建立带有支架移植物的主动脉模型,并将其连接至具有生理流量和压力分布的人工循环。钽标记和NEC用作RSA分析的主动脉参考标记。使用RSA和CT在脉动循环期间测量支架移植物的迁移。使用标准临床方案和中心腔线重建,使用Vitrea后处理软件对通过64 x 0.5 mm光束准直仪获取的CT图像进行分析。循环关闭的模型中的RSA被用作确定支架移植物迁移的参考标准。在脉动循环中确定RSA和CT的测量误差。结果:使用钽标记物在脉动循环期间RSA的平均测量误差+/-标准偏差(最大值)为-0.5 +/- 0.16(0.7)mm。使用NEC,平均(最大)测量误差为-0.4 +/- 0.25(1.1)mm。 CT的平均(最大)测量误差为-1.1 +/- 1.17(2.8)mm。结论:RSA是在脉动环境中测量支架-移植物迁移的准确且可行的工具。在此实验设置中,使用RSA进行的迁移测量比CT更准确。在这项研究中测试的镍钛合金夹子在血管内修复后作为主动脉参考标记可能是可行的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号