首页> 外文期刊>Journal of endourology >Stray radiofrequency current as a cause of urethral strictures after transurethral resection of the prostate.
【24h】

Stray radiofrequency current as a cause of urethral strictures after transurethral resection of the prostate.

机译:经尿道前列腺电切术后,射频杂散电流导致尿道狭窄。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: This study was designed to define the pattern and significance of stray currents induced by two electrosurgical generators (ESGs) in relation to urethral strictures forming after transurethral resection of the prostate (TURP). MATERIALS AND METHODS: A 24F resectoscope irrigated with glycine was activated at various power outputs in different modes, with intact loops and loops with faulty insulation, simulating TURP. The Valleylab and ERBE ESGs were compared for inducing capacitance. An ESG analyzer simulated tissue impedance and recorded the stray currents induced along the resectoscope sheath. A fresh pig liver was used for assessment of tissue damage caused by the currents. RESULTS: In the cutting mode, the ERBE ESG produced a mean stray current of 70 mA with an intact loop and 144 mA with a loop having faulty insulation. The Valleylab ESG produced 150 mA and 161 mA, respectively. In the coagulation mode, the ERBE ESG produced an average leakage current of 35 mA and, with a loop with faulty insulation, 40 mA. The Valleylab ESG produced 148 mA and 151 mA, respectively. CONCLUSIONS: Electrical injury may represent a significant cause of urethral stricture after transurethral electrosurgery. The critical power density of 7.5 W/cm2 (which is likely to cause a urethral burn) may be reached, especially with the use of loops with faulty insulation or nonconductive lubricating gel. The ERBE ESG produced significantly less capacitance, decreasing the risk of urethral electrical burn. Conductive gel prevents dangerous current concentration.
机译:目的:本研究旨在确定与经尿道前列腺电切术(TURP)后尿道狭窄形成有关的两个电外科发生器(ESG)感应的杂散电流的模式和重要性。材料与方法:用甘氨酸灌溉的24F电切镜在不同模式下以不同的功率输出,具有完整的回路和绝缘不良的回路,从而模拟TURP。比较了Valleylab和ERBE ESG的感应电容。 ESG分析仪模拟组织阻抗并记录沿电切镜鞘管感应的杂散电流。新鲜的猪肝用于评估由电流引起的组织损伤。结果:在切割模式下,ERBE ESG产生的平均杂散电流为70 mA(完整回路),为144 mA(具有绝缘不良的回路)。 Valleylab ESG分别产生150 mA和161 mA。在凝结模式下,ERBE ESG产生的平均泄漏电流为35 mA,绝缘故障的回路为40 mA。 Valleylab ESG分别产生148 mA和151 mA。结论:电损伤可能是经尿道电外科手术后尿道狭窄的重要原因。可能会达到7.5 W / cm2的临界功率密度(这可能会引起尿道灼伤),尤其是在使用绝缘不良或不导电的润滑胶圈的情况下。 ERBE ESG产生的电容明显较小,从而降低了尿道电灼伤的风险。导电胶可防止危险电流集中。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号