...
首页> 外文期刊>Journal of dentistry >Factors affecting the accuracy of elastometric impression materials.
【24h】

Factors affecting the accuracy of elastometric impression materials.

机译:影响弹性印模材料准确性的因素。

获取原文
获取原文并翻译 | 示例

摘要

Objectives. The purpose of this study was to evaluate the effects of (1) various impression materials, (2) different storage times and (3) the proportion of inorganic filler on the accuracy and stability of elastometric impression materials. Methods. The impression materials studied included three alginate impression materials (Algiace Z, CAVEX and Jeltrate), five commercial silicone impression materials (Aquasil, Exaflex regular type, Express, Coltex fine and Rapid liner) and two experimental silicone impression materials designed for this study (KE106A and KE106B). Impressions were made of 10 metal dies that mimicked prepared crowns. After an impression was taken, dental stone was immediately poured into the alginate impressions, while the silicone impressions was poured 30 min later and waited for 1 h for setting. The second and third stone dies were made 1 and 24 h later, respectively. The diameters of the occlusal surfaces of the metal dies and stone casts were determined using photographs of the surfaces taken with a Kodak DC 290 digital camera. The pictures were then measured using a photomicrograph digitized integration system to calculate any discrepancy. Because each impression was used to make three rounds of stone dies, two-factor mixed factorial ANOVA was used to evaluate the effect of materials and storage time on the accuracy of the stone casts. The simple effects analysis, combined with multiple comparisons considering the per family type I error rate, was performed following confirmation that an interaction between the two factors was significant. Results. The results showed that: (1) there was a significant interaction effect between materials and storage times on the accuracy of the impressions. (2) Two addition type silicone materials, Aquasil and Exaflex, had the greatest accuracy and stability. (3) The experimental material KE106A had the least accuracy in the first and second rounds and the alginate impression material CAVEX had the least accuracy in the third round. (4) The stabilities of CAVEX and Jeltrate were the least consistent of the 10 materials and decreased significantly with storage time. (5) When the experimental material had a low proportion of filler (KE106A), there was a significantly greater dimensional discrepancy compared to the same material with a higher proportion of filler (KE106B). Conclusions. The accuracies varied among the 10 impression materials over three rounds. Of all the materials, the addition type silicone materials, Aquasil and Exaflex, had relatively greater accuracy and stability. The discrepancy of the alginate impression materials increased with storage time. The large loading of filler showed less discrepancy.
机译:目标。这项研究的目的是评估(1)各种印模材料,(2)不同的储存时间和(3)无机填料的比例对弹性印模材料的准确性和稳定性的影响。方法。所研究的印模材料包括三种藻酸盐印模材料(Algiace Z,CAVEX和Jeltrate),五种市售有机硅印模材料(Aquasil,Exaflex常规类型,Express,Coltex精细和快速内衬)和两种为此实验设计的实验性有机硅印模材料(KE106A)和KE106B)。印象是由模仿准备好的牙冠的10个金属模具制成的。取印模后,立即将牙结石倒入藻酸盐印模中,而硅酮印模则在30分钟后注入,并等待1小时进行固化。第二和第三块石模分别在1和24小时后制成。使用Kodak DC 290数码相机拍摄的表面照片确定金属模具和石材铸件的咬合面直径。然后使用显微照片数字化集成系统测量图片以计算任何差异。因为每个印模用于制作三轮石模,所以使用两因素混合因子ANOVA来评估材料和储存时间对石铸件精度的影响。在确认两个因素之间的相互作用很重要之后,进行了简单的效果分析,并结合了考虑到每个家庭I型错误率的多次比较。结果。结果表明:(1)物料和存放时间之间对印模的准确性有显着的相互作用。 (2)两种添加型有机硅材料Aquasil和Exaflex具有最高的精度和稳定性。 (3)实验材料KE106A在第一轮和第二轮中的精度最低,而藻酸盐压印材料CAVEX在第三轮中的精度最低。 (4)10种材料中CAVEX和Jeltrate的稳定性最低,随着储存时间的延长而降低。 (5)当实验材料的填充物(KE106A)含量低时,与相同的材料中填充物(KE106B)含量高的材料相比,尺寸差异要大得多。结论。在三个回合中,十种印象材料之间的准确性有所不同。在所有材料中,添加型有机硅材料Aquasil和Exaflex具有相对较高的精度和稳定性。藻酸盐印模材料的差异随存储时间的增加而增加。大量填充物显示出较小的差异。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号