...
首页> 外文期刊>Journal of dentistry >Effect of curing mode on the polymerization characteristics of dual-cured resin cement systems.
【24h】

Effect of curing mode on the polymerization characteristics of dual-cured resin cement systems.

机译:固化方式对双固化树脂水泥体系聚合特性的影响。

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECTIVES: To evaluate the effects of different curing conditions on the degree of conversion (DC) of dual-cured cementing systems [combination of bonding agent (BA) and resin cement (RC)] using infrared spectroscopy. METHODS: Four fourth generation products [Scotchbond Multipurpose Plus/RelyX (3M ESPE), Optibond/Nexus 2 (Kerr), All Bond2/Duolink (Bisco), and Bond-It!/Lute-It! (Pentron)], and three fifth generation materials [Bond1/Lute-It! (Pentron), Prime&Bond NT Dual-Cure/Calibra (Dentsply), and Optibond Solo Dual Cure/Nexus 2 (Kerr)] were applied to the surface of a horizontal attenuated-total-reflectance unit, and were polymerized using one of four conditions: self-cure (SC), direct light exposure through glass slide (DLE, XL3000/3M ESPE) or through pre-cured resin discs (shades A2;A4/2mm thick/Z250/3M ESPE). Infrared spectra of the uncured cementing systems were recorded immediately after application to the ATR, after the system was light-cured or left to self-cure, and spectra were obtained 5 and 10min later. DC was calculated using standard techniques of observing changes in aliphatic-to-aromatic peak ratios pre- and post-curing. Data (n=5) were analyzed by two-way repeated measures ANOVA and Tukey's test (p=0.05). RESULTS: Changes in aliphatic-to-aromatic peak ratios before and after placing RC onto the BA demonstrated that a combined layer was created. All groups exhibited higher DC after 10min than after 5min, except the DLE group of Bond-it!/Lute-it!. No significant differences in DC were observed among light-activated groups regardless of the resin disc shade in three of the four fourth generation cementing systems. The SC groups exhibited lower DC than the DLE groups for both fourth and fifth generation products either after 5 or 10min. CONCLUSION: The chemistry of the bonding interface changed when RCs were applied to uncured BAs. The presence of an indirect restoration can decrease the DC of some cementing systems and the self-curing mode leads to lower DC than the light-activating one.
机译:目的:使用红外光谱法评估不同固化条件对双固化胶结体系[粘合剂(BA)和树脂胶结剂(RC)的组合]转化率(DC)的影响。方法:四种第四代产品[Scotchbond Multipurpose Plus / RelyX(3M ESPE),Optibond / Nexus 2(Kerr),All Bond2 / Duolink(Bisco)和Bond-It!/ Lute-It!)。 (Pentron)]和三种第五代材料[Bond1 / Lute-It! (Pentron),Prime&Bond NT Dual-Cure / Calibra(Dentsply)和Optibond Solo Dual Dual-Cure / Nexus 2(Kerr)]应用于水平衰减全反射单元的表面,并使用以下四个条件之一进行聚合:自固化(SC),通过载玻片(DLE,XL3000 / 3M ESPE)或通过预固化的树脂光盘(阴影A2; A4 / 2mm厚度/ Z250 / 3M ESPE)直接曝光。未固化的固井系统的红外光谱在应用到ATR之后,光固化或自固化后立即记录,并在5和10分钟后获得光谱。使用观察固化前和固化后脂族与芳族峰比率变化的标准技术计算DC。通过双向重复测量方差分析和Tukey检验分析数据(n = 5)(p = 0.05)。结果:将RC放置在BA上之前和之后,脂族与芳族峰之比的变化表明形成了一个结合层。除了DLE组的Bond-it!/ Lute-it!外,所有组在10分钟后的DC均高于5分钟。在四个第四代固井系统中的三个中,无论树脂盘的阴影如何,在光活化组之间都没有观察到DC的显着差异。在5或10分钟后,第四和第五代产品的SC组的DC均低于DLE组。结论:将RCs应用于未固化的BAs时,键合界面的化学性质发生了变化。间接修复的存在会降低某些固井系统的DC,而自固化模式会导致DC低于光活化系统。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号