...
首页> 外文期刊>Journal of dentistry >Three-dimensional fit of lithium disilicate partial crowns in uitro
【24h】

Three-dimensional fit of lithium disilicate partial crowns in uitro

机译:uitro二硅酸锂局部冠的三维拟合

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Objectives: A novel three-dimensional scanning technique was used to investigate the effects a one-step and a two-step impression methods can have on the three-dimensional fit of ceramic partial crowns.Methods: An acrylic model of a mandibular first molar was prepared to receive a partial coverage all-ceramic crown (mesio-occlusal-distal inlay preparation with reduction of all cusps and rounded shoulder finish line of buccal wall). Type IV plaster replicates were cast based on one-step single viscosity (OS/SV), one-step dual viscosity (OS/DV), and two-step dual viscosity (TS/DV) impressions. Five partial crowns were fabricated per impression method using hot-pressed lithium disilicate ceramics. Then, preparation and restorations were digitized using a non-contact, white-light scanner featuring self-calibrating optics (overall measurement uncertainty of <5 mum). Data were entered into quality inspection software which superimposed the records (best-fit-algorithm), calculated fit-discrepancies for every pixel, and colour-coded the results to aid visualization. Furthermore, mean quadratic deviations (RMS) were computed and analyzed statistically with a 1-way ANOVA. Scheffe's procedure was applied for multiple comparisons (alpha = 0.05).Results: Mean RMS-values for marginal (internal) surfaces were: OS/SV 70 (20) |xm, OS/DV 78 (34) mum, and TS/DV 107 (52) |xm. Differences among impression techniques were statistically significant atp = 0.006 (0.001). Qualitatively, occlusal ridges and preparation finish lines were over contoured, whereas inner occlusal boxes and the proximal-occlusal isthmus were under contoured.Conclusions: OS/SV and OS/DV impressions resulted in statistically significantly smaller marginal and internal discrepancies than the two-step technique. Clinical significance: Marginal and internal fit of hot-pressed lithium disilicate partial crowns depended on the employed impression technique. One-step impressions are preferred over two-step techniques in many day-to-day clinical situations, especially for the fabrication of partial coverage crown restorations.
机译:目的:采用新颖的三维扫描技术研究单步和两步压印方法对陶瓷局部牙冠的三维配合的影响。方法:下颌第一磨牙的丙烯酸模型为准备接受部分覆盖的全瓷冠(中斜牙-远侧嵌体制备,减少所有牙尖和颊壁的圆形肩部终点线)。根据单步单黏度(OS / SV),一步双黏度(OS / DV)和两步双黏度(TS / DV)印模浇铸IV型石膏复制品。每种压印方法使用热压二硅酸锂陶瓷制作五个局部冠。然后,使用具有自校准光学功能的非接触式白光扫描仪将准备和修复体数字化(总体测量不确定度小于5微米)。将数据输入质量检查软件,该软件会叠加记录(最佳拟合算法),计算每个像素的拟合差异,并对结果进行颜色编码以帮助可视化。此外,计算平均二次偏差(RMS)并使用1向ANOVA进行统计分析。 Scheffe的方法用于多次比较(alpha = 0.05)。结果:边缘(内部)表面的均方根值是:OS / SV 70(20)| xm,OS / DV 78(34)妈妈,TS / DV 107(52)| xm。印象技术之间的差异在统计上具有显着性,atp = 0.006(0.001)。定性地,咬合脊和准备终点线在轮廓之上,而内侧咬合盒和近端峡部在轮廓之下。结论:OS / SV和OS / DV压印产生的统计学差异显着小于两步法技术。临床意义:热压二硅酸锂局部冠的边缘和内部贴合度取决于所采用的压印技术。在许多日常临床情况下,尤其是对于部分覆盖冠修复体的制造而言,一步压印要优于两步压印。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号