Microtensile bond strength of total-etch and self-etching adhesives to caries-affected dentine.

机译:全蚀刻和自蚀刻粘合剂对龋齿影响的牙本质的微拉伸粘合强度。

获取原文
获取原文并翻译 | 示例
           

摘要

Objectives. To evaluate the microtensile bond strength of total-etch or self-etch adhesives to caries-affected versus normal dentine, and to correlate these bond strengths with DIAGNOdent laser fluorescence and Knoop microhardness (KH) measurements of the substrates.Methods. Extracted carious human molars were ground to expose flat surfaces where the caries lesion was surrounded by normal dentine. Surfaces were bonded with either Prime & Bond NT, Scotchbond 1, Clearfil SE Bond or Prompt L-Pop, according to manufacturers' recommendations. A crown was built up using resin composite (Tetric Ceram). After storage in water (37 degrees C, 24 h), teeth were vertically serially sectioned into 0.7 mm thick slabs and trimmed to yield 1 mm(2) test area that contained either caries-affected or normal dentine. Samples were tested in tension in an Instron machine at 1 mm/min. The quality of the dentine just beneath each fractured specimen was measured by laser fluorescence and KH.Results. Total-etch adhesives yielded higher bond strengths than self-etching systems. Significantly lower results were obtained with Prompt L-Pop. All the adhesives attained higher strengths in normal than in caries-affected dentine, but the differences were only significant for Prime & Bond NT and Clearfil SE Bond. Higher laser fluorescence values and lower KH (p<0.001) were recorded in caries-affected dentine compared to normal dentine.Conclusions. The total-etch adhesives evaluated produced higher bond strengths to normal and caries-affected dentine than self-etching systems. Laser fluorescence measurements discriminated caries-affected dentine from normal dentine, and were strongly correlated with KH. However, laser fluorescence and KH did not permit high correlations with resin-dentine bond strengths in caries-affected dentine.
机译:目标。评估全蚀或自蚀粘合剂对龋齿与正常牙本质的微拉伸粘结强度,并将这些粘结强度与基材的DIAGNOdent激光荧光和努氏显微硬度(KH)测量相关联。研磨提取的龋齿人类磨牙,以暴露出平坦的表面,其中龋齿病变被正常的牙本质包围。根据制造商的建议,表面用Prime&Bond NT,Scotchbond 1,Clearfil SE Bond或Prompt L-Pop粘合。使用树脂复合材料(Tetric Ceram)制成表冠。在水中(37摄氏度,24小时)存储后,将牙齿垂直顺次切成0.7毫米厚的平板,并修剪以产生1毫米(2)的测试区域,其中包含患龋的或正常的牙本质。在Instron机器中以1 mm / min的张力测试样品。通过激光荧光和KH测量每个骨折标本下方的牙本质质量。与自蚀刻系统相比,全蚀刻粘合剂产生更高的粘结强度。 Prompt L-Pop获得的结果明显较低。所有的胶粘剂在正常情况下都比龋齿影响的牙本质具有更高的强度,但是差异仅对于Prime&Bond NT和Clearfil SE Bond才有意义。与正常牙本质相比,在龋齿影响的牙本质中记录到更高的激光荧光值和更低的KH(p <0.001)。所评估的全蚀刻胶粘剂与自酸蚀系统相比,对正常和龋齿牙本质的粘合强度更高。激光荧光测量可以将龋齿影响的牙本质与正常的牙本质区分开,并且与KH密切相关。但是,激光荧光和KH不允许与龋齿影响的牙本质中的树脂-牙本质粘合强度高度相关。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号