OBJECTIVES: To evaluate the influence of operator skill on microleakage in class V restorations using two-step bonding systems. METHODS: Two standardized box cavities were made on the buccal and lingual surfaces of 54 human bicuspid teeth, with the cervical margin in dentin. The teeth were randomly assigned to two groups according to the operator's skill. Students group: undergraduate students. Expert group: a dentist with 20 years of clinical experience in dental adhesion. The buccal cavities of each tooth were treated with Prime&Bond NT (two-step total-etch system); the lingual cavities were treated with AdheSE (two-step self-etch system). All cavities were restored by a single calibrated operator with one bulk increment of resin composite (InTens; Ivoclar Vivadent). Specimens were thermocycled, immersed in 2% methylene blue and sectioned in a bucco-lingual plane in the middle of the restorations. They were then examined under a stereomicroscope and scored according to microleakage by two operators who were blind to the specimen preparation. The data was subjected to a multilevel statistical model. RESULTS: The microleakage resulting from the self-etch adhesive was similar in the student and in the expert groups. On the other hand, the total-etch adhesive microleakage within the expert group resulted lower than that within the student group. However, the interaction term skillxadhesive resulted statistically significant at the dentin margin (p=0.0474) but not at the enamel margin (p=0.1267). CONCLUSION: While the total-etch adhesive used in this study showed to be skill-sensitive, the self-etch one proved to be less skill-sensitive in obtaining a reliable seal with dentin.
机译:目的:使用两步粘合系统评估操作人员技能对V级修复中微渗漏的影响。方法:在54只人二尖牙的颊和舌表面上制作了两个标准化的盒子腔,其宫颈边缘位于牙本质中。根据操作员的技能,将牙齿随机分为两组。学生组:大学生。专家组:拥有20年牙科粘连临床经验的牙医。用Prime&Bond NT(两步全刻蚀系统)处理每个牙齿的颊腔。用AdheSE(两步自蚀刻系统)治疗舌腔。所有腔体都由一个经过校准的操作人员修复,并增加了一个树脂增量(InTens; Ivoclar Vivadent)。将样品热循环,浸入2%亚甲蓝中,并在修复体中间的颊舌平面中切成薄片。然后在体视显微镜下对它们进行检查,并由两名不愿进行标本制备的操作员根据微渗漏进行评分。数据经过了多级统计模型。结果:自蚀刻胶粘剂引起的微渗漏在学生和专家组中相似。另一方面,专家组内的总蚀刻粘合剂微渗漏比学生组内的总渗漏微渗漏低。但是,相互作用术语“技能粘合剂”在牙本质边缘处(p = 0.0474)在统计学上显着,而在牙釉质边缘处(p = 0.1267)没有统计学意义。结论:尽管本研究中使用的全蚀刻胶对技能敏感,但自蚀刻胶对获得与牙本质的可靠密封的技能敏感性较低。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号