...
首页> 外文期刊>Journal of dentistry >Hertzian indentation testing of glass-ionomer restoratives: A reliable and clinically relevant testing approach
【24h】

Hertzian indentation testing of glass-ionomer restoratives: A reliable and clinically relevant testing approach

机译:玻璃离聚物修复剂的赫兹压痕测试:一种可靠且与临床相关的测试方法

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Objectives To investigate the load to failure of encapsulated posterior glass-ionomer (GI) restoratives tested under Hertzian indentation and to explore the validity and reproducibility of the test results achieved for consideration of inclusion as an ISO testing protocol. Methods Groups of 20 disc-shaped specimens (10.0 ± 0.1 mm diameter, 3.10 ± 0.03 mm thickness) were prepared (in batches of four) from three encapsulated posterior GI restoratives. Discs were tested while resting freely on a dentine analogue material at 24 h under Hertzian indentation at a rate of 1 mm/min delivered through a 20 mm diameter hard steel ball. The failure mode and fracture origin of the GI specimens was assessed by fractography. Statistical analyses of the load to failure data were conducted using SPSS software (p < 0.05) with the normality and homogeneity of variance of the load to failure data assessed using the Shapiro-Wilk and Levene's test, respectively. Data was also analysed using regression analyses to identify trends within the load to failure data sets. Results The load to failure data for the GI restorative groups investigated were normally distributed (p > 0.05), homogenous (p > 0.05) and not significantly influenced by batch (p > 0.780) or specimen number (p > 0.447) although significant differences (p < 0.05) between the GI restorative materials were evident. Fractographic analysis identified smooth fracture surfaces parallel to the loading axis where the failure mode was bottom initiated radial cracking. The mean coefficient of variation (CoV) for the GI restorative load to failure data sets achieved using Hertzian indentation testing was 7%. Significance The failure mode and fracture origin of the GI restoratives tested using Hertzian indentation is representative of the clinical situation in vivo. The reliability of the load to failure data sets produced were improved compared with routinely employed mechanical testing approaches suggesting the possibility of inclusion as an ISO testing protocol.
机译:目的研究在赫兹压痕下测试的封装后玻璃离聚物(GI)修复剂的破坏负荷,并探讨将测试结果考虑为ISO测试方案的有效性和可重复性。方法用三种封装的后胃肠道修复剂制备20个圆盘状样品(直径10.0±0.1毫米,厚度3.10±0.03毫米),每组四个(一组)。测试圆盘时,将其在赫兹压痕下以1 mm / min的速度通过20 mm直径的硬钢球输送,在24小时内自由地搁置在牙本质类似物上。胃肠道标本的破坏模式和断裂起源通过分形术进行评估。使用SPSS软件(p <0.05)对失效数据进行了统计分析,分别使用Shapiro-Wilk和Levene检验评估了失效数据的方差的正态性和同质性。还使用回归分析对数据进行了分析,以识别负荷失败数据集中的趋势。结果研究的胃肠修复组的失败负荷数据呈正态分布(p> 0.05),均质(p> 0.05)且不受批次(p> 0.780)或样本数量(p> 0.447)的显着影响,尽管有显着差异(胃肠道修复材料之间的差异显着(p <0.05)。分形分析确定平行于载荷轴的光滑断裂表面,其中破坏模式是底部引发的径向裂纹。使用Hertzian压痕测试获得的GI修复失败数据集的平均变异系数(CoV)为7%。重要性使用赫兹压痕测试的胃肠道修复剂的失效模式和骨折起源是体内临床情况的代表。与常规采用的机械测试方法相比,所产生的载荷对故障数据集的可靠性得到了提高,表明可能包含在ISO测试协议中。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号