...
首页> 外文期刊>Journal of dentistry >Active application improves the bonding performance of self-etch adhesives to dentin.
【24h】

Active application improves the bonding performance of self-etch adhesives to dentin.

机译:主动应用可改善自蚀刻粘合剂与牙本质的粘合性能。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

OBJECTIVES: To evaluate the effect of application method on immediate and 6-month resin-dentin microtensile bond strength (muTBS) and nanoleakage (NL) of three one-step self-etch adhesives systems (Clearfil S(3) Bond (S3), Xeno III (XE) and Adper Prompt L-Pop (AD)). METHODS: The oclusal enamel of 30 human molar was removed in order to expose a flat dentin surface. The adhesives were applied under two modes: inactive (IN) or active (AC) application. After light-curing (600mW/cm(2) for 10s), composite buildups were constructed incrementally and sectioned to obtain bonded sticks (0.8mm(2)) to be tested in tension immediately (IM) or after 6 months (6M) of water storage. For NL, three bonded sticks from each tooth at each time were coated with nail varnish, placed in silver nitrate and polished down with SiC paper. The muTBS data were submitted to a two-way ANOVA and Tukey's test for each adhesive (alpha=0.05). RESULTS: The AC showed higher muTBS to dentin when compared to IN in both periods of time (p=0.001). Only for AD, lower muTBS was seen after 6M for IN and AC techniques. XE and S3 adhesives applied under IN showed a higher amount of silver penetration throughout the hybrid layer. Low silver nitrate deposition was seen for these adhesives under AC. After 6M, AD showed a higher amount of silver nitrate uptake under IN and AC techniques. CONCLUSIONS: AC improves the bonding performance of all one-step self-etch adhesive systems tested regardless of the time and this tendency was maintained over time.
机译:目的:评估施涂方法对三种单步自蚀刻胶粘剂系统(Clearfil S(3)Bond(S3))的即时和6个月树脂-牙本质微拉伸粘合强度(muTBS)和纳米渗漏(NL)的影响, Xeno III(XE)和Adper Prompt L-Pop(AD))。方法:去除30个人牙的牙釉质,以暴露平坦的牙本质表面。粘合剂以两种方式施加:非活性(IN)或活性(AC)施加。光固化(600mW / cm(2)持续10s)后,逐步构建复合物并切成薄片,以获得粘合棒(0.8mm(2)),立即(IM)或6个月(6M)拉伸后进行拉伸测试蓄水。对于NL,每次取自每个牙齿的三个粘结棒都涂有指甲油,置于硝酸银中,并用SiC纸抛光。将每种粘合剂的muTBS数据进行双向ANOVA和Tukey检验(alpha = 0.05)。结果:在两个时间段内,AC与IN相比对牙本质的muTBS均更高(p = 0.001)。仅对于AD,IN和AC技术在6M之后观察到更低的muTBS。在IN下应用的XE和S3粘合剂在整个杂化层中显示出更高的银渗透率。在交流电下,这些粘合剂的硝酸银沉积量较低。 6M后,AD在IN和AC技术下显示出更高的硝酸银吸收量。结论:AC改善了测试的所有一步式自蚀刻胶粘剂系统的粘合性能,而与时间无关,并且这种趋势随着时间的推移得以保持。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号