首页> 外文期刊>Journal of dentistry >Temperature variation at the external root surface during 980-nm diode laser irradiation in the root canal.
【24h】

Temperature variation at the external root surface during 980-nm diode laser irradiation in the root canal.

机译:在根管中980 nm二极管激光辐照期间,根外部表面的温度变化。

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECTIVE: To assess the temperature variation in the cervical, middle and apical thirds of root external wall, caused by 980-nm diode laser irradiation with different parameters. METHODS: The roots of 90 canines, had their canals instrumented and were randomly distributed into 3 groups (n=30) according to the laser potency (1.5 W, 3.0 W and 5.0 W). Each group was subdivided into 3 (n=10) according to the frequency (CM, 100 Hz and 1000 Hz), and each subgroup divided into 2 (n=5): dried canal or filled with distilled water. The maximum temperature values were collected by 3 thermocouples located at each third of the root external wall and recorded by digital thermometers. RESULTS: The groups irradiated in the continuous mode (CM) presented the highest values (11.82+/-5.78), regardless of the canals were dry or not, which were statistically different (p<0.01) from those obtained with 100 Hz (6.22+/-3.64) and 1000 Hz (6.00+/-3.36), which presented no statistical difference between them (p>0.01). The groups irradiated with 5.0 W presented the greatest temperature variation (12.15+/-5.14), followed by 3.0 W (7.88+/-3.92) and 1.5 W (4.02+/-2.16), differing between them (p<0.01). The cervical third of the root presented the highest temperature rises (9.68+/-5.80), followed by the middle (7.66+/-4.87) and apical (6.70+/-4.23), with statistical difference among them (p<0.01). After 30s from the end of irradiation, all the specimens presented temperature variation lower than 10 degrees C. CONCLUSIONS: Application of 980-nm diode laser in the root, at 1.5 W in all operating modes, and 3.0 W, in the pulsed mode, for 20s, can safely be used in endodontic treatment, irrespective of the presence of humidity.
机译:目的:评估不同参数的980nm二极管激光辐照引起的根外壁颈,中,根尖的温度变化。方法:对90只犬的根部进行根管治疗,并根据激光强度(1.5 W,3.0 W和5.0 W)将其随机分为3组(n = 30)。根据频率(CM,100 Hz和1000 Hz)将每个组细分为3个(n = 10),将每个组细分为2个(n = 5):干渠或充满蒸馏水。最高温度值由位于根部外壁各三分之一处的3个热电偶收集,并由数字温度计记录。结果:以连续模式(CM)照射的组呈现最高值(11.82 +/- 5.78),无论运河是否干燥,与100 Hz(6.22)的统计差异(p <0.01) (+/- 3.64)和1000 Hz(6.00 +/- 3.36),两者之间无统计学差异(p> 0.01)。用5.0 W照射的组温度变化最大(12.15 +/- 5.14),其次是3.0 W(7.88 +/- 3.92)和1.5 W(4.02 +/- 2.16),两者之间存在差异(p <0.01)。根颈的三分之一出现最高的温度升高(9.68 +/- 5.80),其次是中部(7.66 +/- 4.87)和根尖(6.70 +/- 4.23),二者之间具有统计学差异(p <0.01) 。从辐照结束30秒后,所有标本的温度变化均低于10摄氏度。结论:在根部使用980 nm二极管激光器,在所有工作模式下的功率为1.5 W,在脉冲模式下的功率为3.0 W,在20秒钟内,无论是否潮湿,均可安全地用于牙髓治疗。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号