Effect of temperature on post-cure polymerization of bulk-fill composites

机译:温度对填充复合材料固化后聚合的影响

获取原文
获取原文并翻译 | 示例
       

摘要

Objectives: To investigate the 24 h post-cure polymerization and the effect of temperature on the post-cure polymerization of one conventional and three bulk-fill composite materials. Methods: A conventional composite GrandioSO (GR) and three bulk-fill composites: Tetric EvoCeram Bulk Fill (TECBF), Quixfil (QF) and X-tra fil (XF) were investigated. The samples were cured for 20 s with irradiance of 1090 mW/cm2. Composite samples were divided into two groups: the "room-temperature" group (RT, n = 5) and the "body-temperature" group (BT, n = 5) and they were stored in dark at 20°C and 37°C, respectively. Measurements of degree of conversion (DC) were made immediately after curing (0 h) and 24 h post-cure (24 h). To analyse the extent of post-cure DC increase, the DC values of 0 h-RT/24 h-RT and 0 h-BT/24 h-BT were compared. To analyse the difference in DC between RT and BT, the DC values of 0 h-RT/0 h-BT and 24 h-RT/24 h-BT were compared. Results: DC increase 24 h post-cure was significant for all composites and ranged between 6.3% and 8.2% in RT and between 12.5% and 15.7% in BT. All composites demonstrated a higher DC in 24 h-BT compared to 24 h-RT. The difference was statistically significant for GR, TECBF and QF. Conclusions: All composites demonstrated a significant post-cure effect after 24 h. Post-cure temperature increase from 20°C to 37°C yielded a higher post-cure DC increase. Clinical significance: Due to the temperature effect on the final DC, studies performed at composite samples at room temperature may record more inferior properties than these attained in the oral cavity.
机译:目的:研究固化后24小时聚合反应和温度对一种常规和三种填充复合材料的固化后聚合反应的影响。方法:研究了常规复合材料GrandioSO(GR)和三种填充复合材料:Tetric EvoCeram填充材料(TECBF),Quixfil(QF)和X-tra fil(XF)。样品在1090 mW / cm2的辐射下固化20 s。将复合样品分为两组:“室温”组(RT,n = 5)和“体温”组(BT,n = 5),它们分别在黑暗中于20°C和37°C下保存C分别。固化后(0 h)和固化后24 h(24 h)立即进行转化度(DC)的测量。为了分析固化后DC的增加程度,比较了0 h-RT / 24 h-RT和0 h-BT / 24 h-BT的DC值。为了分析RT和BT之间的DC差异,比较了0h-RT / 0h-BT和24h-RT / 24h-BT的DC值。结果:所有复合材料的固化后24小时DC均显着升高,RT范围在6.3%至8.2%之间,BT范围在12.5%至15.7%之间。与24 h-RT相比,所有复合材料在24 h-BT中均表现出更高的DC。对于GR,TECBF和QF,差异具有统计学意义。结论:所有复合材料在24 h后均表现出显着的后固化效果。后固化温度从20°C升高到37°C产生更高的后固化DC升高。临床意义:由于温度对最终DC的影响,在室温下对复合样品进行的研究可能会发现比口腔中获得的性能更差的性能。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号