摘要

Objectives This study aimed to quantify tooth wear in upper anterior teeth using a new CAD-CAM Laser scanning machine, tool maker microscope and conventional tooth wear index. Methods Fifty participants (25 males and 25 females, mean age = 25 ± 4 years) were assessed for incisal tooth wear of upper anterior teeth using Smith and Knight clinical tooth wear index (TWI) on two occasions, the study baseline and 1 year later. Stone dies for each tooth were prepared and scanned using the CAD-CAM Laser Cercon System. Scanned images were printed and examined under a toolmaker microscope to quantify tooth wear and then the dies were directly assessed under the microscope to measure tooth wear. The Wilcoxon Signed Ranks Test was used to analyze the data. Results TWI scores for incisal edges were 0-3 and were similar at both occasions. Score 4 was not detected. Wear values measured by directly assessing the dies under the toolmaker microscope (range = 113-150 μm, mean = 130 ± 20 μm) were significantly more than those measured from Cercon Digital Machine images (range = 52-80 μm, mean = 68 ± 23 μm) and both showed significant differences between the two occasions. Conclusions Wear progression in upper anterior teeth was effectively detected by directly measuring the dies or the images of dies under toolmaker microscope. Measuring the dies of worn dentition directly under tool maker microscope enabled detection of wear progression more accurately than measuring die images obtained with Cercon Digital Machine. Conventional method was the least sensitive for tooth wear quantification and was unable to identify wear progression in most cases.
机译:目的本研究旨在使用新型CAD-CAM激光扫描仪,工具制造商显微镜和常规牙齿磨损指数来量化上前牙的牙齿磨损。方法使用Smith和Knight临床牙齿磨损指数(TWI)两次评估50名参与者(男25例,女25例,平均年龄= 25±4岁)的上前牙切牙,研究基线和1年后。准备每个牙齿的石模,并使用CAD-CAM Laser Cercon System进行扫描。打印扫描图像并在工具显微镜下检查以量化牙齿磨损,然后在显微镜下直接评估模具以测量牙齿磨损。使用威尔科克森符号秩检验来分析数据。结果切缘的TWI得分为0-3,在两种情况下相似。未检测到分数4。通过直接在工具制造商显微镜下评估模具而测得的磨损值(范围= 113-150μm,平均值= 130±20μm)显着大于通过Cercon Digital Machine图像所测量的值(范围= 52-80μm,平均值= 68± 23μm),并且两种情况均显示出显着差异。结论通过直接在模具显微镜下测量模具或模具的图像,可以有效地检测上前牙的磨损进展。与使用Cercon Digital Machine获得的模具图像相比,直接在工具制造商的显微镜下测量磨损的牙列模具可以更准确地检测磨损进程。传统方法对牙齿磨损的量化最不敏感,并且在大多数情况下无法确定磨损的进展。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号