...
首页> 外文期刊>Journal of dentistry >Influence of surface layer removal of shade guide tabs on the measured color by spectrophotometer and spectroradiometer.
【24h】

Influence of surface layer removal of shade guide tabs on the measured color by spectrophotometer and spectroradiometer.

机译:分光光度计和分光光度计去除遮阴片的表面层对测得颜色的影响。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

OBJECTIVES: To determine the changes in color parameters of Vitapan 3D-Master shade guide tabs by a spectrophotometer (SP) or a spectroradiometer (SR), and by the removal of the surface layer of the tabs that was performed to make a flat measuring surface for the SP color measurement. METHODS: Color of the shade tabs was measured before and after removing the surface layer of the tabs using SP and SR. Correlations between the color parameters between the original (OR) and the surface layer removed (RM) tabs and between the SP and the SR measurements were determined (alpha=0.05). RESULTS: Based on SP, the lightness, chroma, CIE a* and b* values measured after the surface layer removal were higher than those of the original tabs except a few cases. Based on SR, the chroma and CIE a* and b* values measured after surface layer removal were higher than those of the original tabs except a few cases; however, in case of the lightness, the changes varied by the shade designation. Type of instrument influenced the changes in color parameters based on paired t-test (p<0.05). The color parameters of the OR and RM tabs showed correlations based on both SP and SR measurements (r=0.952-0.997 and p<0.01); however, color difference between the SP-RM and SR-OR tabs was in the range of 18.1-27.0 DeltaE(ab)(*) units (mean: 23.3+/-2.2). CONCLUSIONS: When the color of tooth-shaped objects is measured with a spectrophotometer or a spectroradiometer, measurement protocols should be specified because color difference by the surface layer removal and the instrument was high.
机译:目的:通过分光光度计(SP)或分光辐射计(SR)并通过去除用于形成平坦测量表面的薄片表面层,来确定Vitapan 3D-Master阴影引导薄片的颜色参数变化用于SP颜色测量。方法:使用SP和SR在去除标签的表面层之前和之后测量阴影标签的颜色。确定了原始(OR)标签与去除的表面层(RM)标签之间的颜色参数之间以及SP与SR测量值之间的颜色参数之间的相关性(alpha = 0.05)。结果:基于SP,除少数情况外,表面层去除后测得的亮度,色度,CIE a *和b *值均高于原始标签。基于SR,除少数情况外,表面层去除后测得的色度和CIE a *和b *值均高于原始标签。但是,对于明度,变化会因阴影名称而异。仪器类型影响基于配对t检验的颜色参数的变化(p <0.05)。基于SP和SR测量,OR和RM选项卡的颜色参数显示出相关性(r = 0.952-0.997和p <0.01);但是,SP-RM和SR-OR选项卡之间的色差在18.1-27.0 DeltaE(ab)(*)单位范围内(平均值:23.3 +/- 2.2)。结论:使用分光光度计或分光光度计测量牙齿状物体的颜色时,应指定测量规程,因为去除表面层和仪器的色差很大。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号