首页> 外文期刊>Journal of applied microbiology >The removal of bacterial biofilm from water-filled tubes using axiallypropagated ultrasound
【24h】

The removal of bacterial biofilm from water-filled tubes using axiallypropagated ultrasound

机译:使用轴向传播的超声去除充水管中的细菌生物膜

获取原文
获取原文并翻译 | 示例

摘要

Axially propagated ultrasound (APU) has been used to remove mineralized Proteus mirabilis biofilms from water-filled glass tubes. Pulses (30 s) of ultrasound at frequencies ranging from 350 to 20 kHz were applied to one end of the tubes and the extent of biofilm removal was assessed by infra-red absorptiometry. The removal of biofilm from 7 cm tubes by two 30 s pulses of APU at 150 kHz (54.8%) was comparable to thar (60.9%) achieved by sonication at 33 kHz in a conventional sonic cleaning bath. In 50 cm tubes, three 30 s pulses of APU from the 20 kHz transducer removed 87.5% of the biofilm. The equivalent results for APU at 150 kHz and 350 kHz were 66.8% and 31.3%, respectively. These observations suggest that the axial propagation of ultrasound along lengths of water-filled tubing offers the prospect of on-line cleaning of systems such as heat-exchanger pipework.
机译:轴向传播超声(APU)已用于从充满水的玻璃管中去除矿化的奇异变形杆菌生物膜。将超声脉冲(30 s)以350至20 kHz的频率施加到试管的一端,并通过红外吸光法评估生物膜去除的程度。在150 kHz下通过两个30 s的APU脉冲从7 cm管中去除生物膜的效果与在常规超声波清洗浴中以33 kHz进行超声处理获得的沙尔(60.9%)相当。在50 cm的试管中,来自20 kHz换能器的三个30 s的APU脉冲去除了87.5%的生物膜。在150 kHz和350 kHz下APU的等效结果分别为66.8%和31.3%。这些观察结果表明,超声波沿着充满水的管道的长度方向传播,为在线清洗热交换器管道等系统提供了前景。