Histologic and clinical response to varying density settings with a fractionally scanned carbon dioxide laser.

机译:用部分扫描的二氧化碳激光对不同密度设置的组织学和临床反应。

获取原文
获取原文并翻译 | 示例

摘要

OBJECTIVE: An evaluation of the histological and clinical response to varying density settings (-10%, 0, and 10% overlap) with a fractionally scanned CO2 laser. STUDY DESIGN: Clinical and histological study evaluating abdominoplasty excised tissue for depth of penetration and width of tissue ablated with varying density and energy settings utilizing a scanned microsecond pulsed CO2 laser. These parameters were correlated clinically with patients treated with similar density settings. PARTICIPANTS: Fifteen patients were enrolled with 5 patients in each group: group 1 (density 1 settings), group 2 (density 2 settings) and group 3 (density 3 settings). MAIN OUTCOME: Histological differences of width and depth of tissue ablated with varying density settings and correlation with photodamage improvement clinically. METHODS: Six samples of excised abdominoplasty tissue were treated with increased energy and density settings and were evaluated histologically. Clinically, 15 patients with photodamage to the face were randomized to receive a fractional CO2 laser treatment with density levels ranging from 1 to 3. RESULTS: Microarrays of tissue injury were visualized with multiple areas of superficial to full-thickness epidermal thermal damage. As energy increased (90 W to 100 W), the width of basophilic coagulation of the subepidermal collagen increased. Increased density paralleled increased depth of penetration of subepidermal coagulation. Patient assessment of discomfort, erythema, edema, and satisfaction with the procedure was proportional to increasing densities. CONCLUSION: A fractional CO2 laser produces photorejuvenation, erythema, edema and discomfort in proportion with the depth and extent of epidermal and subepidermal thermal damage.
机译:目的:用部分扫描的CO2激光评估不同密度设置(-10%,0和10%重叠)的组织学和临床反应。研究设计:临床和组织学研究,通过扫描微秒脉冲CO2激光器评估切除的腹部组织的穿透深度和组织宽度,密度和能量设置各不相同,从而消融。这些参数在临床上与使用相似密度设置治疗的患者相关。对象:每组15例患者,每组5例:第1组(密度1设置),第2组(密度2设置)和第3组(密度3设置)。主要观察结果:组织密度和组织深度的组织学差异随着密度设置的变化而消融,并且与临床光损伤的改善相关。方法:对六个切除的腹部成形术组织样品进行增加能量和密度设置的处理,并进行组织学评估。临床上,将15例对面部有光损伤的患者随机接受密度等级为1至3的部分CO2激光治疗。结果:组织损伤的微阵列可见,表浅至全层表皮热损伤多个区域。随着能量增加(从90 W到100 W),表皮下胶原的嗜碱性凝结宽度增加。密度增加与表皮下凝血的渗透深度增加平行。病人对不适,红斑,水肿和手术满意度的评估与密度增加成正比。结论:分数CO 2激光产生光子嫩肤,红斑,水肿和不适感,与表皮和表皮下热损伤的深度和程度成正比。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号