首页> 外文期刊>Clinical chemistry and laboratory medicine: CCLM >Analytical precision of the Urolizer for the determination of the BONN-Risk-Index (BRI) for calcium oxalate urolithiasis and evaluation of the influence of 24-h urine storage at moderate temperatures on BRI.
【24h】

Analytical precision of the Urolizer for the determination of the BONN-Risk-Index (BRI) for calcium oxalate urolithiasis and evaluation of the influence of 24-h urine storage at moderate temperatures on BRI.

机译:用于测定草酸钙尿石症的BONN-风险指数(BRI)的Urolizer的分析精度以及在中等温度下24小时尿液储存对BRI的影响的评估。

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND: Since its first publication in 2000, the BONN-Risk-Index (BRI) has been successfully used to determine the calcium oxalate (CaOx) crystallization risk from urine samples. To date, a BRI-measuring device, the "Urolizer", has been developed, operating automatically and requiring only a minimum of preparation. Two major objectives were pursued: determination of Urolizer precision, and determination of the influence of 24-h urine storage at moderate temperatures on BRI. METHODS: 24-h urine samples from 52 CaOx stone-formers were collected. A total of 37 urine samples were used for the investigation of Urolizer precision by performing six independent BRI determinations in series. In total, 30 samples were taken for additional investigation of urine storability. Each sample was measured thrice: directly after collection, after 24-h storage at T=21 degrees C, and after 24-h cooling at T=4 degrees C. Outcomes were statistically tested for identity with regard to the immediately obtained results. RESULTS: Repeat measurements for evaluation of Urolizer precision revealed statistical identity of data (p-0.05). 24-h storage of urine at both tested temperatures did not significantly affect BRI (p-0.05). CONCLUSIONS: The pilot-run Urolizer shows high analytical reliability. The innovative analysis device may be especially suited for urologists specializing in urolithiasis treatment. The possibility for urine storage at moderate temperatures without loss of analysis quality further demonstrates the applicability of the BRI method.
机译:背景:自2000年首次发表以来,BONN风险指数(BRI)已成功用于确定尿液样本中草酸钙(CaOx)结晶的风险。迄今为止,已经开发出一种BRI测量设备“ Urolizer”,它可以自动运行,只需要最少的准备工作。追求两个主要目标:确定尿液发生器的精确度,以及确定在中等温度下24小时尿液储存对BRI的影响。方法:收集52个CaOx结石形成者的24小时尿液样本。通过连续进行六次独立的BRI测定,总共使用了37个尿液样本来研究尿液仪的精度。总共采集了30个样品用于尿液可贮藏性的进一步调查。每个样品测量三次:直接在收集后,在T = 21摄氏度下储存24小时后,在T = 4摄氏度下冷却24小时后。就立即获得的结果对结果进行统计学检验。结果:重复测量,以评估Urolizer精度揭示数据的统计同一性(p-0.05)。在两个测试温度下尿液24小时储存对BRI均无明显影响(p-0.05)。结论:试运行的Urolizer具有很高的分析可靠性。该创新的分析设备可能特别适合专门从事尿石症治疗的泌尿科医师。在中等温度下储存尿液而不损失分析质量的可能性进一步证明了BRI方法的适用性。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号