Validity and reliability of the CAM-ICU Flowsheet to diagnose delirium in surgical ICU patients.

机译:CAM-ICU流程图在外科ICU患者中诊断del妄的有效性和可靠性。

获取原文
获取原文并翻译 | 示例

摘要

PURPOSE: Delirium occurs frequently in critical care but often remains undiagnosed because delirium monitoring is often dismissed as being too time-consuming. This study determined the validity and reliability of the CAM-ICU Flowsheet, criteria in intubated patients. MATERIALS AND METHODS: With permission from our institution's ethics committee, patients of a 31-bed surgical intensive care unit department were screened for delirium (1) by a psychiatrist as the reference rater using the 4 delirium criteria of the Diagnostic and Statistical Manual of Mental Diseases, Fourth Edition (DSM-IV), and (2) by 2 physician investigators using a German translation of the CAM-ICU Flowsheet. RESULTS: Fifty-four surgical ICU patients underwent the complete protocol assessment with paired observations; 46% were diagnosed with delirium by the reference rater (n = 25), 9% had hyperactive delirium (n = 5), and 37% were hypoactive (n = 20). The CAM-ICU Flowsheet investigators had sensitivities of 88% (95% confidence interval, 69%-98%) and 92% (74%-99%), specificities of 100% (85%-100%), very high interrater reliability (kappa, 0.96; 0.87-1.00), and needed 50 seconds (interquartile range, 40-120 seconds) in patients with delirium vs 45 seconds (interquartile range, 40-75 seconds) in those without delirium to complete assessments. CONCLUSIONS: The CAM-ICU Flowsheet has high sensitivity, high specificity, and very high interrater reliability. False-negative ratings can occur infrequently and mostly reflect the fluctuating course of delirium. The CAM-ICU Flowsheet is a valid, reliable, and quickly performed bedside delirium instrument.
机译:目的:Deli妄在重症监护病房中经常发生,但由于remains妄监测太耗时,因此经常被忽视,因此常常未被诊断。这项研究确定了CAM-ICU流程表(插管患者的标准)的有效性和可靠性。材料与方法:经本机构伦理委员会的许可,由精神科医生筛查31张病床的外科重症监护病房的患者是否有ir妄(1)作为参考评定者,使用《心理诊断和统计手册》中的4种del妄标准。疾病,第四版(DSM-IV),以及(2)由2位医师研究人员使用CAM-ICU流程图的德语译本编写。结果:54例外科ICU患者接受了配对观察的完整方案评估。参考评定者诊断为del妄的占46%(n = 25),hyper妄亢进的占9%(n = 5),运动亢进的37妄为37%(n = 20)。 CAM-ICU流程调查员的灵敏度分别为88%(95%置信区间,69%-98%)和92%(74%-99%),特异性为100%(85%-100%),极高的间作可靠性(kappa,0.96; 0.87-1.00),and妄患者需要50秒(四分位间距40-120秒),而del妄患者需要45秒(四分位间距40-75秒)才能完成评估。结论:CAM-ICU流程图具有高灵敏度,高特异性和非常高的间位可靠性。假阴性评定很少发生,并且大部分反映了ir妄的波动过程。 CAM-ICU流程图是一种有效,可靠且执行迅速的床旁del妄仪器。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号