A simple and reproducible high performance liquid chromatography-tandem mass spectrometric method was developed for methocarbamol analysis in human plasma. Methocarbamol and the internal standard (IS) were extracted by a protein precipitation method. Under isocratic separation condition the chromatographic run time was 3.0 min. The calibration curve was linear over a range of 150-12,000 ng/mL with good intraday assay and interday assay precision (CV% < 10.9%). The method was proven to be sensitive and selective for the analysis of methocarbamol in human plasma for bioequivalence study.
机译:建立了一种简单,可重现的高效液相色谱-串联质谱法,用于人血浆中的甲氧氨基酚分析。甲硫脲和内标(IS)通过蛋白质沉淀法提取。在等度分离条件下,色谱运行时间为3.0分钟。校准曲线在150-12,000 ng / mL的范围内呈线性,具有良好的日内检测和日间检测精度(CV%<10.9%)。该方法被证明对分析人血浆中的甲硫脲具有灵敏性和选择性,可用于生物等效性研究。