首页> 外文期刊>Journal of chromatography, B. Analytical technologies in the biomedical and life sciences >SPE-GC-MS for the sampling and determination of unmetabolized styrene in urine
【24h】

SPE-GC-MS for the sampling and determination of unmetabolized styrene in urine

机译:SPE-GC-MS用于尿液中未代谢苯乙烯的采样和测定

获取原文
获取原文并翻译 | 示例
       

摘要

The urinary excretion of unmetabolized styrene can be a very good indicator for biomonitoring styrene in occupationally exposed people. The use of a new urine sampling system, involving a solid-phase extraction cartridge, offers several advantages for determining styrene. The advantages are especially related to the pre-analytical phase of styrene determination, which may be influenced by many variables. The effect on styrene recovery of sorbent type, eluting solvent, elution volume, elution flow-rate, and the addition of methanol to the washing solvent, was evaluated by experimental design methodology. As a result, Oasis HLB cartridges were selected for urine sampling, as well as 1.5 mL of ethyl acetate at 0.5 mL/min for eluting the retained styrene. These conditions were then applied to the validation of the solid-phase extraction combined with GC-MS method for the sampling and analysis of unmetabolized styrene in urine. The overall uncertainty was in the 12-22% range and the limit of detection was 2.2 mu g/L for a 4 mL urine sample. The stability of styrene has been studied both in cartridges and in vials under different storage periods. After I month period the styrene stored on cartridges at room temperature remained stable, whereas this is not the case for styrene recovery from vials. The results obtained indicate that on-site solid-phase extraction of urine can provide a simple, accurate and reproducible sampling and analytical method for the biomonitoring of styrene in urine. (c) 2005 Elsevier B.V. All rights reserved.
机译:未代谢苯乙烯的尿排泄可以很好地指示对职业接触人群进行苯乙烯生物监测。新的尿液采样系统(包括固相萃取柱)的使用为测定苯乙烯提供了多个优势。这些优势尤其与苯乙烯测定的分析前阶段有关,这可能会受到许多变量的影响。通过实验设计方法评估了吸附剂类型,洗脱溶剂,洗脱体积,洗脱流速以及向洗涤溶剂中添加甲醇对苯乙烯回收率的影响。结果,选择了Oasis HLB小柱进行尿液采样,并选择了0.5 mL / min的1.5 mL乙酸乙酯用于洗脱保留的苯乙烯。然后将这些条件应用于固相萃取的验证,并结合GC-MS方法对尿中未代谢的苯乙烯进行采样和分析。总体不确定度在12-22%范围内,对于4 mL尿液样品,检出限为2.2μg / L。已经研究了在不同储存时间下在弹药筒和小瓶中苯乙烯的稳定性。一个月后,室温下储存在药筒中的苯乙烯保持稳定,而从小瓶中回收苯乙烯则不是这种情况。获得的结果表明,现场固相萃取尿液可以为尿液中苯乙烯的生物监测提供一种简单,准确和可重现的采样和分析方法。 (c)2005 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号