首页> 外文期刊>Journal of chromatography, B. Analytical technologies in the biomedical and life sciences >Simple means to alleviate sensitivity loss by trifluoroacetic acid (TFA) mobile phases in the hydrophilic interaction chromatography-electro, spray tandem mass spectrometric (HILIC-ESI/MS/MS) bioanalysis of basic compounds
【24h】

Simple means to alleviate sensitivity loss by trifluoroacetic acid (TFA) mobile phases in the hydrophilic interaction chromatography-electro, spray tandem mass spectrometric (HILIC-ESI/MS/MS) bioanalysis of basic compounds

机译:在碱性化合物的亲水相互作用色谱-电喷雾串联质谱(HILIC-ESI / MS / MS)生物分析中,减轻三氟乙酸(TFA)流动相引起的灵敏度损失的简单方法

获取原文
获取原文并翻译 | 示例

摘要

Trifluoroacetic acid (TFA) is a commonly used additive in HPLC and LC-MS analysis of basic compounds. It is also routinely added to aqueous-organic mobile phases utilized in the hydrophilic interaction chromatography-electrospray tandem mass spectrometry (HILIC-ESI/MS/MS) technique used in our laboratories for bioanalysis. However, TFA is known to suppress the ESI signals of analytes due to its ability to form gas-phase ion pairs with positively-charged analyte ions. The most common method to overcome this problem involves the post-column addition of a mixture of propionic acid and isopropanol. However the post-column addition setup requires additional pumps and is not desirable for continuous analysis of large amounts of samples. In this paper we present a simple yet very effective means of minimizing the negative effect of TFA in bioanalysis by direct addition of 0.5% acetic acid or 1% propionic acid to mobile phases containing either 0.025 or 0.05% TFA. A factor of two- to five-fold signal enhancement was achieved for eight basic compounds studied. Furthermore, chromatography integrity was maintained even with the addition of acetic acid and propionic acid to existing TFA mobile phases. This method has been successfully applied to the HILIC-ESI/MS/MS high-throughput analysis of extracted biological samples to support pre-clinical and clinical studies. (c) 2005 Elsevier B.V. All rights reserved.
机译:三氟乙酸(TFA)是碱性化合物的HPLC和LC-MS分析中常用的添加剂。它也通常添加到我们实验室中用于生物分析的亲水相互作用色谱-电喷雾串联质谱(HILIC-ESI / MS / MS)技术中使用的水-有机流动相中。然而,已知TFA由于其能够与带正电的分析物离子形成气相离子对而抑制分析物的ESI信号。解决此问题的最常用方法是在色谱柱后添加丙酸和异丙醇的混合物。但是,柱后添加设置需要额外的泵,对于大量样品的连续分析是不希望的。在本文中,我们提出了一种简单而有效的方法,可通过直接向含有0.025或0.05%TFA的流动相中添加0.5%乙酸或1%丙酸来最小化TFA在生物分析中的负面影响。研究的八种碱性化合物的信号增强达到了两倍至五倍。此外,即使在现有的TFA流动相中加入乙酸和丙酸,也能保持色谱完整性。该方法已成功应用于提取的生物样品的HILIC-ESI / MS / MS高通量分析,以支持临床前和临床研究。 (c)2005 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号