首页> 外文期刊>Journal of chromatography, B. Analytical technologies in the biomedical and life sciences >Rapid and sensitive determination of fentanyl in dog plasma by on-line solid-phase extraction integrated with a hydrophilic column coupled to tandem mass spectrometry
【24h】

Rapid and sensitive determination of fentanyl in dog plasma by on-line solid-phase extraction integrated with a hydrophilic column coupled to tandem mass spectrometry

机译:固相萃取-串联质谱联用在线固相萃取快速,灵敏地测定狗血浆中的芬太尼

获取原文
获取原文并翻译 | 示例
           

摘要

We have developed and validated a method for the quantification of fentanyl, a synthetic opioid, in dog plasma by on-line SPE with a hydrophilic column coupled to tandem mass spectrometry in positive electrospray mode. A column-switching instrument with 10-port valve and two HPLC pumping systems were employed. Deuterated fentanyl served as the internal standard. A Waters Oasis HLB extraction column and a Waters Atlantis HILIC Silica analytical column in a column-switching set-up with gradient elution were utilized. Both fentanyl (analyte) and the internal standard (fentanyl-d5) were determined via multiple reaction monitoring (MRM) and the MS/MS ion transitions monitored were m/z 337.0/188.0 and 342.0/188.0, respectively. Each plasma sample was chromatographed within 5 min. The calibration curves were linear over a widely range of 0.01-50 ng/mL using weighted linear regression analysis (1/x). The low limit of quantitation was 0.01 ng/mL. The intra- and inter-day accuracy ranged from 102 to 112% and the overall precision was less than 3%. The recoveries ranged from 90 to 105% in plasma at the concentrations of 0.04, 0.4, 4 and 40 ng/mL. No influence of freeze/thaw and long-term stability were observed. This validated method has been successfully applied to analyze the dog plasma samples of a pharmacokinetics study. (c) 2007 Elsevier B.V. All rights reserved.
机译:我们已经开发并验证了一种通过在线SPE与亲水性色谱柱联用串联质谱在正电喷雾模式下对狗血浆中的芬太尼(一种合成的阿片类药物)进行定量的方法。使用具有10通阀和两个HPLC泵系统的柱切换仪。氘代芬太尼用作内标。在梯度切换的柱切换装置中,使用了Waters Oasis HLB萃取柱和Waters Atlantis HILIC硅胶分析柱。芬太尼(分析物)和内标物(芬太尼-d5)均通过多反应监测(MRM)测定,监测的MS / MS离子跃迁分别为m / z 337.0 / 188.0和342.0 / 188.0。每个血浆样品在5分钟内进行色谱分离。使用加权线性回归分析(1 / x),校准曲线在0.01-50 ng / mL的宽范围内呈线性。定量下限为0.01 ng / mL。日内和日间准确度介于102%至112%之间,整体准确度低于3%。血浆浓度为0.04、0.4、4和40 ng / mL时,回收率在90%至105%之间。没有观察到冻融的影响和长期稳定性。这种经过验证的方法已成功地应用于分析药代动力学研究中的狗血浆样品。 (c)2007 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号