A simple and effective multi-residue method was developed and validated for the analysis of 26 organochlorine pesticide residues in Alpinia oxyphylla by a gas chromatography with an electron capture detector (GC-ECD). The target pesticides were extracted by sonication and cleaned up with florisil solid phase extraction and sulphuric acid. Some crucial parameters, including extraction solvent and time, sorbent type, elute solvent and concentration of sulphuric acid were optimized to improve the performance of sample preparation procedure. The optimized method gave high sensitivity with detection limit ranging from 0.1 to 2.0 mu g/kg. Matrix-matched calibration was employed for the quantification, and a wide linear range (from 1.0 to 1000 mu g/kg) with r(2) values ranging from 0.9971 to 0.9998 was obtained. For the majority of the tested pesticides, the average recoveries were in acceptable range (between 70% and 110%) with relative standard deviation values below 15.0%. Matrix effect was evaluated for target compounds through the study of ratio of peak area obtained in the solvent and blank matrix. The proposed method was applied to simultaneously analyze 26 pesticides in 55 batches of Alpinia oxyphylla samples. 3 samples were found to be positive with four pesticides (alpha-BHC, quintozene, trans-chlordane and op'-DDD), which were confirmed by gas chromatography-mass spectrometry (GC-MS) in selective ion monitoring (SIM) mode. (C) 2016 Elsevier B.V. All rights reserved.
机译:建立了一种简单有效的多残留方法,并通过带有电子捕获检测器(GC-ECD)的气相色谱法分析了叶羽扇豆中26种有机氯农药残留。通过超声提取目标农药,并用弗洛里西尔固相萃取和硫酸进行净化。优化了一些关键参数,包括萃取溶剂和时间,吸附剂类型,洗脱溶剂和硫酸浓度,以改善样品制备过程的性能。优化后的方法灵敏度高,检出限为0.1至2.0μg / kg。基质匹配校准用于定量,并获得了宽线性范围(1.0至1000μg / kg),r(2)值介于0.9971至0.9998之间。对于大多数测试农药,平均回收率在可接受的范围内(70%至110%之间),相对标准偏差值低于15.0%。通过研究在溶剂和空白基质中获得的峰面积之比,评估了目标化合物的基质效应。该方法可同时分析55批次高产阿尔卑斯山样品中的26种农药。 3种样品中的4种农药(α-BHC,喹烯,反式氯丹和op'-DDD)为阳性,这是通过气相色谱-质谱法(GC-MS)在选择性离子监测(SIM)模式下确认的。 (C)2016 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号