首页> 外文期刊>Journal of chromatography, B. Analytical technologies in the biomedical and life sciences >Simultaneous GC-MS determination of eight phthalates in total and migrated portions of plasticized polymeric toys and childcare articles
【24h】

Simultaneous GC-MS determination of eight phthalates in total and migrated portions of plasticized polymeric toys and childcare articles

机译:GC-MS同时测定增塑聚合物玩具和育儿用品的全部和迁移部分中的八种邻苯二甲酸酯

获取原文
获取原文并翻译 | 示例
           

摘要

A gas chromatography/mass spectrometric method was developed for the simultaneous determination of eight phthalic acid esters (PAEs) in toys and child care articles that are made of plasticized plastic. The novel method was used to determine the total concentration of the PAEs in addition to the migrated PAEs values into artificial saliva, under conditions that simulate real life situations. The extraction method, which was developed for the first time to determine the total concentration of PAEs, utilized a novel optimization of four parameters involving the solvent, time, temperature and weight of sample. The PAEs were extracted with tetrahydrofuran, as extraction the solvent, and using the ultrasonic water bath shaker for 30 min, at room temperature. Another extraction method was developed to determine the migrated PAEs into artificial saliva at pH 6.2 and 37 degrees C, implementing a liquid-liquid extraction with chloroform. Both methods were subjected to validation steps in terms of linearity, precision, accuracy and recovery, which ensured that all obtained results were well within the norms of acceptable limits and specifications. The analytes were separated at the following retention times: 4.99, 5.21, 5.31, 6.63, 7.41, 9.05 min for di-"isobutyl" phthalate (DIBP), dibutyl phthalate (DBP), bis(2-methoxyethyl)phthalate (DMEP), benzyl butyl phthalate (BBP), dibutyl phthalate (DEHP) and di-n-octyl phthalate (DnOP), respectively. The chromatographic peaks corresponding to di-"isononyl" phthalate (DINP) and di-"isononyl" phthalate (DIDP), were separated, using the extracted ion chromatogram (EIC) mode within the time ranges of 8.05-12.10 min for DINP and 8.50-14.50 min for DIDP. The instrument detection limits for DIBP, DBP, DMEP, BBP, DEHP, DnOP, DINP and DIDP were determined at 0.100, 0.100, 0.045, 0.035, 0.015, 0.370, 0.320, 0.260 mu g/ml, respectively. The calibration curve working ranges were determined at 0.5-25 mu g/ml for DIBP, DBP, DMEP, BBP and DEHP, 2-100 mu g/ml for DnOP and 5-100 mu g/ml for DINP and DIDP. The coefficients of variation (precision) for the total PAEs method were in the range 0.55-12.10% and for the migration method were in the range 0.72-7.70%. Recovery values for total PAEs and for the migrated PAEs were ranged within 90.6-111.7% and 86.3-117.2%; respectively. Both developed methods were used to survey the Jordanian market, where twenty seven samples were collected and tested for plastic type, total PAEs and migrated PAEs. Seventeen of those samples were found to be polyvinyl chloride (PVC), and all of them containing total PAEs having concentrations in excess of the allowed limit of 0.1% (w/w). The rest of the samples were non-PVC and only one of them containing PAEs, but below the allowed limit. In contrast, all the migration results were found to be well within the allowed limits. It was also found that as the PAEs total concentration increase, the corresponding migrated value increase, while the opposite trend holds for in the PAEs molecular weight. (C) 2015 Elsevier B.V. All rights reserved.
机译:开发了一种气相色谱/质谱法,用于同时测定由增塑塑料制成的玩具和儿童护理制品中的八种邻苯二甲酸酯(PAE)。在模拟现实生活的条件下,除了将PAEs值迁移到人工唾液中之外,该新方法还用于确定PAEs的总浓度。萃取方法是首次开发来确定PAE的总浓度,它利用了四个参数的新颖优化,包括溶剂,时间,温度和样品重量。用四氢呋喃萃取PAE,作为萃取溶剂,并在室温下使用超声水浴振荡器摇动30分钟。开发了另一种提取方法,以确定在pH 6.2和37摄氏度下迁移到人工唾液中的PAE,用氯仿进行液-液提取。两种方法均经过线性,精密度,准确性和回收率验证步骤,以确保所有获得的结果均在可接受的限制和规格标准之内。在以下保留时间分离分析物:邻苯二甲酸二异丁酯(DIBP),邻苯二甲酸二丁酯(DBP),邻苯二甲酸二(2-甲氧基乙基)酯(4.99,5.21,5.31,6.63,7.41,9.05分钟)邻苯二甲酸苄基丁酯(BBP),邻苯二甲酸二丁酯(DEHP)和邻苯二甲酸二正辛酯(DnOP)。使用提取的离子色谱图(EIC)模式在DINP的8.05-12.10分钟和8.50的时间范围内分离了对应于邻苯二甲酸二“异壬酯”和邻苯二甲酸二“异壬酯”的色谱峰对于DIDP,为-14.50分钟。 DIBP,DBP,DMEP,BBP,DEHP,DnOP,DINP和DIDP的仪器检出限分别确定为0.100、0.100、0.045、0.035、0.015、0.370、0.320、0.260μg / ml。校准曲线的工作范围对于DIBP,DBP,DMEP,BBP和DEHP确定为0.5-25μg/ ml,对于DnOP为2-100μg/ ml,对于DINP和DIDP为5-100μg/ ml。总PAEs方法的变异系数(精度)在0.55-12.10%范围内,而迁移方法在0.72-7.70%范围内。总PAE和迁移的PAE的回收率在90.6-111.7%和86.3-117.2%之间;分别。两种开发的方法都用于调查约旦市场,在那里收集了27个样品并测试了塑料类型,总PAE和迁移的PAE。这些样品中有17个是聚氯乙烯(PVC),并且所有样品中的全部PAE的浓度都超过了0.1%(w / w)的允许限值。其余样品均为非PVC,其中只有一个包含PAE,但低于允许限值。相反,发现所有迁移结果均在允许的范围内。还发现,随着PAEs总浓度的增加,相应的迁移值增加,而PAEs分子量的变化趋势相反。 (C)2015 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号