首页> 外文期刊>Journal of chromatography, B. Analytical technologies in the biomedical and life sciences >Methodology for a rapid and simultaneous determination of total cysteine, homocysteine, cysteinylglycine and glutathione in plasma by isocratic RP-HPLC
【24h】

Methodology for a rapid and simultaneous determination of total cysteine, homocysteine, cysteinylglycine and glutathione in plasma by isocratic RP-HPLC

机译:等度RP-HPLC快速同时测定血浆中总半胱氨酸,高半胱氨酸,半胱氨酸甘氨酸和谷胱甘肽的方法学

获取原文
获取原文并翻译 | 示例
           

摘要

Alterations in the plasma aminothiols levels can be considered as important biomarkers for the diagnosis and screening of several human disorders, namely cardiovascular diseases. We aimed to optimize a rapid, sensitive and accurate RP-HPLC methodology with fluorescence detection, for the simultaneous determination of the total concentrations of cysteine, homocysteine, cysteinylglycine and glutathione in blood plasma, as well as its application to the evaluation of those thiols levels in plasma of a group of Azorean subjects. Aminothiols were reduced with tri-n-butylphosphine and derivatized with a thiol-specific fluorogenic reagent ammonium 7-fluorobenzo-2-oxa-1,3-diazole-4-sulphonate. The thiols adducts were separated by an isocratic elution on a Platinum EPS C18 analytical column (53mm×7mm I.D., 3μm) using a phosphate buffer containing 4% of acetonitrile as a mobile phase. Results indicated an excellent linearity for all the analytes over their respective concentration ranges with correlation coefficients (r~2) ≥0.99. The LOD for the four plasma thiols was lower than 0.10μmol/L, while LOQ varied from 0.5 to 15μmol/L. For both intra-and inter-day precision, the RSD (%) values were lower than 1.9%, and the CV (%) values were found under 0.5%. The recovery ranged from 92% to 100% indicating a high degree of the method's accuracy. This method allows a simultaneous, complete analysis of the four plasma aminothiols and the internal standard in 6min. By reducing the total run time, a larger number of analysis can be performed daily.
机译:血浆氨基硫醇水平的变化可以被认为是诊断和筛选几种人类疾病(即心血管疾病)的重要生物标志物。我们旨在通过荧光检测优化快速,灵敏和准确的RP-HPLC方法,用于同时测定血浆中半胱氨酸,高半胱氨酸,半胱氨酸甘氨酸和谷胱甘肽的总浓度,并将其应用于评估这些硫醇的水平在一组亚速尔族受试者的血浆中。用三正丁基膦还原氨基硫醇,并用硫醇特异性的荧光试剂7-氟苯并-2-氧杂-1,3-二唑-4-磺酸铵衍生化。使用含4%乙腈的磷酸盐缓冲液作为流动相,在Platinum EPS C18分析柱(53mm×7mm I.D.,3μm)上通过等度洗脱分离硫醇加合物。结果表明,所有分析物在各自浓度范围内均具有极好的线性,相关系数(r〜2)≥0.99。四种血浆硫醇的LOD低于0.10μmol/ L,而LOQ在0.5至15μmol/ L之间。对于日内和日间精度,RSD(%)值均低于1.9%,而CV(%)值低于0.5%。回收率从92%到100%不等,表明该方法的准确性很高。该方法可在6分钟内同时,全面分析四种血浆氨基硫醇和内标。通过减少总运行时间,每天可以执行大量分析。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号