An aptamer based lateral flow strip based on competitive format was developed for on-site rapid detection of ochratoxin A (OTA) in Astragalus membranaceus. Some crucial parameters that might influence the sensitive detection, such as the characterization of the colloidal gold, size and shape of gold nanoparticles (AuNPs), amount of AuNPs-aptamer conjugate, migration rate and the addition amount of methanol, were investigated to provide the optimum assay performance. To perform the test, 1 g sample was extracted with 2.5 mL of methanol-water (80:20, v/v) and diluted by 4-fold running buffer to eliminate the matrix and methanol interferences. Under optimized conditions, the aptamer-based assay showed a visual limit of detection (LOD) of 1 ng mL(-1), and with no significant cross-reactivity with several homologous toxins. The whole detection could be completed within 15 min without special equipment because of available visual results. One out of nine A. membranaceus samples was found to be positive of OTA, which was in a good agreement with those obtained from LC-MS/MS analysis. The results demonstrated that the aptamer-based lateral flow assay could be used as a rapid, reliable, cost-effective and robust on-site screening technique for mycotoxins at trace level in complex matrices without special instrumentation. (C) 2016 Elsevier B.V. All rights reserved.
机译:开发了一种基于竞争性形式的基于适体的侧向流动条,用于现场快速检测黄芪中曲霉毒素A(OTA)。研究了一些可能影响灵敏检测的关键参数,例如胶体金的表征,金纳米颗粒的大小和形状,AuNPs-适体共轭物的量,迁移速率和甲醇的添加量,以提供最佳测定性能。为了进行测试,用2.5 mL甲醇-水(80:20,v / v)提取1 g样品,并用4倍运行缓冲液稀释,以消除基质和甲醇的干扰。在优化的条件下,基于适体的测定显示出1 ng mL(-1)的视觉检测极限(LOD),并且与几种同源毒素没有明显的交叉反应性。由于可获得的视觉结果,整个检测无需特殊设备即可在15分钟内完成。发现九份膜曲霉样本中有一份为OTA阳性,这与从LC-MS / MS分析获得的样本非常吻合。结果表明,基于适体的侧向流动检测技术可在复杂的基质中快速,可靠,具有成本效益和强大的现场筛查真菌毒素的技术,而无需特殊仪器。 (C)2016 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号