A procedure for separation and quantitation of methylmercury by capillary electrophoresis using sample stacking as the injection technique is presented. The CE conditions have been optimized in order to separate the methylmercury from the excess cysteine peak and to concentrate large volumes of sample obtaining a low detection limit. Under the proposed operational conditions, the detection limit (S/N=3) was 12 ng g(-1) and the limit of quantitation (S/N=10) was 20 ng g(-1) with a linear range of 20-100 ng g(-1) (as methylmercury in samples). The method was tested using different reference materials with a certified methylmercury content.
机译:提出了一种使用样品堆叠作为进样技术的毛细管电泳分离和定量甲基汞的方法。对CE条件进行了优化,以便将甲基汞与过量的半胱氨酸峰分离,并浓缩大量样品,从而获得较低的检测限。在建议的操作条件下,检测限(S / N = 3)为12 ng g(-1),定量限(S / N = 10)为20 ng g(-1),线性范围为20 -100 ng g(-1)(作为样品中的甲基汞)。该方法使用具有标准甲基汞含量的其他参考材料进行了测试。