首页> 外文期刊>Journal of chromatography, A: Including electrophoresis and other separation methods >INTEGRATED SYSTEM FOR ON-LINE GAS AND LIQUID CHROMATOGRAPHY WITH A SINGLE MASS SPECTROMETRIC DETECTOR FOR THE AUTOMATED ANALYSIS OF ENVIRONMENTAL SAMPLES
【24h】

INTEGRATED SYSTEM FOR ON-LINE GAS AND LIQUID CHROMATOGRAPHY WITH A SINGLE MASS SPECTROMETRIC DETECTOR FOR THE AUTOMATED ANALYSIS OF ENVIRONMENTAL SAMPLES

机译:带有单质谱检测器的在线气相色谱和液相色谱集成系统,用于环境样品的自动分析

获取原文
获取原文并翻译 | 示例
       

摘要

An integrated system has been developed which combines liquid (LC) and gas (GC) chromatographic separation with a single mass spectrometer (MS). On-line solid-phase extraction (SPE) of 10-200 mi aqueous samples on a short (10x2.0 mm I.D.) precolumn packed with a styrene-divinylbenzene copolymer is used for analyte enrichment. The trace-enrichment procedure was automated by means of a PROSPEKT cartridge-exchange/solvent-selection/valve-switching unit. After sample loading, the precolumn is eluted on-line in two subsequent runs, first onto the GC-MS system and, next, onto the LC-MS system using a particle beam (PB) interface. Prior to entering the PB-MS, the LC eluent passes through the flow cell of a UV diode-array detector (DAD). Both GC-MS and LC-PB-MS generate classical electron ionisation (EI) and chemical ionisation (CI) spectra which are useful for the identification of low- and sub-mu g/l concentrations of environmental pollutants covering a wide polarity and volatility range. The LC-DAD data provide additional means for quantitation and yield complementary spectral information. All three detection systems (GC-MS, LC-DAD, LC-PB-MS) and the trace-enrichment procedure are fully automated and controlled from the keyboard of the central computer. With such a 'MULTIANALYSIS' system GO-MS, LC-DAD and LC-MS data of the same sample can be obtained within 3 h. The system was optimised with nine chlorinated pesticides in drinking water as test mixture. With 100-ml samples detection limits in GC-MS were 0.0005-0.03 mu g/l, and in LC-PB-MS 0.5-7 mu g/l, both in the full-scan (EI) mode. Negative chemical ionisation (NCI) with methane as reagent gas improved the sensitivity of six halogenated compounds 3- to 30-fold and provided relevant information for structural elucidation of unknown compounds in real-world samples. LC-DAD detection limits varied from 0.01 to 0.05 mu g/l. Relative standard deviations (R.S.D.) of retention times were less than 0.2% in all systems, R.S.D.s of peak areas were 5-15% for GC-MS and LC-PB-MS and less than 5% for LC-DAD. The 'MULTIANALYSIS' system was used to analyse surface water samples and river sediment extracts; several pollutants were detected and identified.
机译:已开发出一种集成系统,该系统将液相色谱(LC)和气相色谱(GC)分离与单个质谱仪(MS)相结合。在填充有苯乙烯-二乙烯基苯共聚物的短(10x2.0 mm I.D.)预柱上,在线固相萃取(SPE)10-200 mi水性样品可用于分析物富集。痕量富集程序通过PROSPEKT滤芯交换/溶剂选择/阀切换单元自动进行。样品上样后,预柱在随后的两次运行中在线洗脱,首先通过颗粒束(PB)界面洗脱到GC-MS系统上,然后洗脱到LC-MS系统上。在进入PB-MS之前,LC洗脱液会通过UV二极管阵列检测器(DAD)的流通池。 GC-MS和LC-PB-MS均可产生经典的电子电离(EI)和化学电离(CI)光谱,可用于鉴定低极性和亚微克/升浓度的环境污染物,涵盖广泛的极性和挥发性范围。 LC-DAD数据为定量提供了其他手段,并产生了互补的光谱信息。所有这三种检测系统(GC-MS,LC-DAD,LC-PB-MS)和痕量富集程序都是全自动的,并可以通过中央计算机的键盘进行控制。使用这种“ MULTIANALYSIS”系统,可以在3小时内获得同一样品的GO-MS,LC-DAD和LC-MS数据。使用饮用水中的九种氯化农药作为测试混合物对系统进行了优化。在全扫描(EI)模式下,对于100 ml样品,GC-MS中的检测限为0.0005-0.03μg / l,而LC-PB-MS中的检测限为0.5-7μg / l。以甲烷为反应气的负化学电离(NCI)将六种卤代化合物的灵敏度提高了3到30倍,并为实际样品中未知化合物的结构解析提供了相关信息。 LC-DAD的检出限为0.01至0.05μg / l。在所有系统中,保留时间的相对标准偏差(R.S.D.)均小于0.2%,GC-MS和LC-PB-MS峰面积的R.S.D.s为5-15%,而LC-DAD的峰面积的R.S.D.s小于5%。 “ MULTIANALYSIS”系统用于分析地表水样品和河流沉积物提取物。检测并鉴定了几种污染物。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号