首页> 外文期刊>Journal of chromatography, B. Analytical technologies in the biomedical and life sciences >Optimization of on-line solid phase extraction and HPLC conditions using response surface methodology for determination of WM-5 in mouse plasma and its application to pharmacokinetic study
【24h】

Optimization of on-line solid phase extraction and HPLC conditions using response surface methodology for determination of WM-5 in mouse plasma and its application to pharmacokinetic study

机译:响应面法测定小鼠血浆中WM-5的在线固相萃取和HPLC条件的优化及其在药代动力学研究中的应用

获取原文
获取原文并翻译 | 示例
           

摘要

Response surface methodology (RSM) was utilized for rapid and systematic optimization of on-line solid-phase extraction (SPE) parameters to maximize the response and separation of WM-5. The optimization was performed with Box-Behnken designs. Four major parameters were investigated for their contributions to the response and separation of WM-5, with a total of 29 experiments being performed for each instrument, respectively. Quantitative determination of WM-5 in mouse plasma was performed to evaluate the statistical significance of the parameters on chromatographic response. A fully automated on-line SPE and high-performance liquid chromatography (HPLC) with diode array detection (DAD) method was developed for the determination of WM-5 in mouse plasma. Calibration curve with good linearity (r=0.9989) was obtained in the range of 20-4000. ng/mL in mouse plasma. The limit of detection (LOD) and lower limit of quantification (LLOQ) of the assay were 6. ng/mL and 20. ng/mL, respectively. The overall intra-day and the inter-day variations were less than 1.90%. The recovery of the method was in the range of 93.74-96.33% with RSD less than 3.06%. The optimized method demonstrated good performance in terms of specificity, LLOQ, linearity, recovery, precision and accuracy, and was successfully applied to quantify WM-5 in mouse plasma to support the pharmacokinetic study.
机译:响应面方法(RSM)用于快速,系统地优化在线固相萃取(SPE)参数,以最大化WM-5的响应和分离度。优化是通过Box-Behnken设计进行的。研究了四个主要参数对WM-5响应和分离的贡献,每种仪器分别进行了29个实验。进行了小鼠血浆中WM-5的定量测定,以评估参数对色谱响应的统计学意义。开发了一种全自动在线SPE和带有二极管阵列检测(DAD)方法的高效液相色谱(HPLC),用于测定小鼠血浆中的WM-5。在20-4000范围内获得了具有良好线性度的校正曲线(r = 0.9989)。小鼠血浆中的ng / mL。该测定的检出限(LOD)和定量下限(LLOQ)分别为6. ng / mL和20 ng / mL。日内和日间总体波动小于1.90%。该方法的回收率在93.74-96.33%范围内,RSD小于3.06%。优化后的方法在特异性,LLOQ,线性,回收率,精密度和准确性方面均表现出良好的性能,并成功应用于定量小鼠血浆中的WM-5,以支持药代动力学研究。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号