We have developed a high resolution liquid chromatographic separation with electrospray ionization (ESI) mass spectrometry detection for the combined analysis of twelve acylcarnitines and seven amino acids commonly measured in newborn screening heritable metabolic disorders. Samples were prepared by punching 3.2. mm disks out of dried blood spots and extracting with a mixture of methanol and 0.1% formic acid containing stable isotopically labeled internal standards. Analysis was performed on an UHPLC system using a HILIC amide, 2.1. mm × 50. mm, 1.7 μm column. A normal phase gradient, employing 10. mM ammonium acetate in 90:10 acetonitrile/water for mobile phase B and 0.1% formic acid in water for mobile phase A, was used. Optimized multiple reaction monitoring (MRM) was used for detection of amino acids and acylcarnitines on a Waters Premier mass spectrometer. Quantification of analytes was performed using internal calibration by fortification of sodium heparin whole blood with analytes at appropriate levels to encompass the range around the reported cut-off values. The method was fully validated with respect to precision, accuracy, recovery, linearity, matrix suppression and extraction robustness. Precision and accuracy were evaluated over 3 days and determined to be acceptable with an overall precision within 10% and accuracy within 15% of theoretical for all analytes except for acetylcarnitne at one fortified level, which quantitated 21.8% lower than the expected value. This method is suitable as a second-tier test for newborn screening of specific disorders associated with abnormal levels of acylcarnitines and amino acids, potentially reducing false positive cases and shortening the time to diagnosis.
机译:我们已经开发了一种高分辨液相色谱分离和电喷雾电离(ESI)质谱检测技术,用于对新生儿筛查可遗传代谢疾病中通常测量的十二种酰基肉碱和七种氨基酸进行综合分析。通过冲压3.2制备样品。从干燥的血斑中取出mm圆盘,然后用含有稳定同位素标记的内标的甲醇和0.1%甲酸的混合物萃取。使用HILIC酰胺2.1在UHPLC系统上进行分析。 mm×50. mm,1.7μm色谱柱。使用正相梯度,对于流动相B,使用在90:10乙腈/水中的10 mM乙酸铵,对于流动相A,使用在水中的0.1%甲酸。优化的多反应监测(MRM)用于在Waters Premier质谱仪上检测氨基酸和酰基肉碱。使用内部校准,通过使用适当水平的分析物强化肝素钠全血以涵盖报告的临界值附近的范围,使用内部校准对分析物进行定量。该方法在精度,准确性,回收率,线性,基质抑制和提取稳健性方面均得到了充分验证。在3天内评估了精度和准确度,对于所有分析物,其总体精度在理论值的10%以内,准确性在15%以内,是可接受的,但乙酰基肉碱在一个强化水平下的定量值比预期值低21.8%。此方法适合作为第二级测试,用于新生儿筛查与酰基肉碱和氨基酸异常水平相关的特定疾病,从而可能减少假阳性病例并缩短诊断时间。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号