首页> 外文期刊>Journal of chromatography, A: Including electrophoresis and other separation methods >Design of a compressed air modulator to be used in comprehensive multidimensional gas chromatography and its application in the determination of pesticide residues in grapes
【24h】

Design of a compressed air modulator to be used in comprehensive multidimensional gas chromatography and its application in the determination of pesticide residues in grapes

机译:用于综合多维气相色谱的压缩空气调节器的设计及其在葡萄中农药残留测定中的应用

获取原文
获取原文并翻译 | 示例
           

摘要

In this study, a new modulator that is simple, robust and presents low operation costs, was developed. This modulator uses compressed air to cool two small portions in the first centimeters of the second chromatographic column of a comprehensive multidimensional gas chromatography (GC x GC) system. The results show a variation in the peak area less than 3 and 5% to alkanes and pesticides, respectively. The standard deviations for the retention times in the first and second dimension are around 0.05 min and 0.05 s for all the compounds. The system was optimized with n-alkanes. The GC x GC system proposed was applied in the determination of pyrethroid pesticides (bifenthrin, cypermethrin, deltamethrin, fenvaler_ate, esfenvalerate, cis- and trans-permethrin) in grape samples. samples were extracted by the mini-Luke modified method and pesticides were quantified by comprehensive multidimensional gas chromatogra_phy with micro electron-capture detection (_ECD). The values of method limit of quantification (LOQ) were 0.01-0.02mgkg~-1 for all studied pyrethroid and the values of recovery were between 94.3 and 115.2%, with good precision (RSD < 18.4%), demonstrating that the performance of the total method con_sisting of a modified Luke extraction method and determination by GC x GC-_μECD are satisfactory. This study also showed that the system using a modulator with a double jet of compressed air has the poten_tial for application in the analysis of a wider range of pesticide residues in other commodities since it provides low values of LOQ with acceptable accuracy and precision.
机译:在这项研究中,开发了一种简单,耐用且具有较低运行成本的新型调制器。该调制器使用压缩空气来冷却综合多维气相色谱(GC x GC)系统的第二色谱柱的第一厘米中的两个小部分。结果表明,烷烃和农药的峰面积变化分别小于3和5%。所有化合物在第一维和第二维上的保留时间的标准偏差约为0.05分钟和0.05 s。该系统用正构烷烃进行了优化。提出的GC x GC系统用于测定葡萄样品中的拟除虫菊酯类农药(联苯菊酯,氯氰菊酯,溴氰菊酯,杀虫菊酯,乙草戊酸酯,顺式和反式氯菊酯)。采用mini-Luke改进方法提取样品,并通过具有微电子捕获检测(_ECD)的综合多维气相色谱法对农药进行定量。所有拟除虫菊酯的方法定量限(LOQ)值为0.01-0.02mgkg〜-1,回收率在94.3%至115.2%之间,精密度较高(RSD <18.4%),证明了该方法的性能。包括改良的Luke提取方法的总方法以及通过GC xGC-μECD进行测定均令人满意。这项研究还表明,使用带有双压缩空气喷射器的调制器的系统具有潜力,可用于分析其他商品中更广泛的农药残留,因为它提供了较低的LOQ值,并且具有可接受的准确性和精密度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号